Origin Data Lab Technical Field Note #30: Bare hands, cotton gloves, black nitrile: a standard hand detector finds 88%, 50% and 4% of visible hands
-
Updated
Nov 21, 2026 - Python
Origin Data Lab Technical Field Note #30: Bare hands, cotton gloves, black nitrile: a standard hand detector finds 88%, 50% and 4% of visible hands
Origin Data Lab Technical Field Note #27: Ten working days, every second checked: work gloves halved the usable time, because the hand detector missed gloved hands
Origin Data Lab Technical Field Note #23: Hands are in view 75% of the time; an off-the-shelf detector finds a quarter of them: MediaPipe on head-mounted fisheye work video
Origin Data Lab Technical Field Note #15: How much does head motion blur egocentric video? Measured over 2 h 25 min of real work
Origin Data Lab Technical Field Note #28: Usable hours are not usable clips: how many 10-second clips an hour of real work gives
Origin Data Lab Technical Field Note #24: 3D hand skeletons from a head-mounted stereo pair during real work: hands 28–42 cm away, palm segments stable to 4–10% per frame
Origin Data Lab Technical Field Note #25: How much of 2.6 hours of egocentric work video is usable? A per-second QC index: 85% sharp, about half with hands at work
Origin Data Lab Technical Field Note #29: How much of a real workday is walking? The IMU says 6%, in 73 short trips an hour
Origin Data Lab Technical Field Note #11: Is the factory calibration good enough? Independent validation of a fisheye stereo camera over 237,000 corner observations
Origin Data Lab Technical Field Note #18: Don't pair stereo frames by their counters: per-session offsets of up to 3,009 frames, true sync 15 µs
Origin Data Lab Technical Field Note #21: Head pose from stereo alone during real work: rotation checked against the gyroscope, translation against the accelerometer
Origin Data Lab Technical Field Note #20: Stable is not the same as correct: the calibration file saved with every recording was for 800×600, the video is 1600×1200
Origin Data Lab Technical Field Note #22: Checking stereo sync from the outside: a flashing monitor puts left and right within 0.15 ms
Origin Data Lab Technical Field Note #10: Can you trust the clocks? Frame, stereo and IMU timing of a stereo+IMU egocentric rig, measured
Origin Data Lab Technical Field Note #16: Does the data hold up over a real shift? Recording integrity and calibration over 2 h 25 min of head-mounted work
Origin Data Lab Technical Field Note #17: Where does a head-mounted camera point during real work? View direction, hands and self-occlusion over 2 h 25 min
Origin Data Lab Technical Field Note #12: Why your calibration board disappears at 60 cm: measured ChArUco detection limits on a wide-angle egocentric camera
Origin Data Lab Technical Field Note #31: Finding gloved hands: an open-vocabulary detector recovers most of the usable time lost to gloves
Origin Data Lab Technical Field Note #14: IMU noise and bias of a stereo+IMU egocentric rig, measured from static recordings
Origin Data Lab Technical Field Note #19: Four days of real work, 8.9 hours, 957,336 stereo frames: does a head-mounted stereo+IMU rig behave the same every day?
To associate your repository with the technical-field-note topic, visit your repo's landing page and select "manage topics."