Small Windows-friendly CLI tools for backing up and restoring Marlin settings and updating the firmware of STM32 printer boards over USB (DFU).
The neighboring Marlin checkout is configured for an Artillery Hornet with an
Artillery Ruby board, Artillery_Ruby PlatformIO environment, 250000 baud and
EEPROM settings. These are defaults and context, not a substitute for checking
the connected printer and firmware before use.
| What | Needed for | Notes |
|---|---|---|
| Windows with Python 3.9 or newer | everything | Tested with Python 3.12. pyserial is installed by the setup below. |
| Printer connected by USB and switched on | everything | Idle, not printing. Close Pronterface, slicers and other programs that use the printer's port. |
Marlin with EEPROM_SETTINGS |
saving settings (--save, M500) |
Without it, restored settings last only until the next power-off. |
| PlatformIO (recommended) | building the firmware; flashing with its dfu-util |
Found on PATH or in %USERPROFILE%\.platformio. If dfu-util is missing, install it with pio pkg install -g --tool platformio/tool-dfuutil. |
| STM32CubeProgrammer | flashing, if PlatformIO is not installed | Cannot build: an existing build is flashed. Found on PATH or in its default install folder. |
| WinUSB driver for the board in DFU mode | flashing, flash backups | Installed by STM32CubeProgrammer. With only PlatformIO, install it once with Zadig for "STM32 BOOTLOADER" while the board is in DFU mode. |
A board that M997 puts into DFU mode |
update-firmware, backup-flash, restore-flash |
True for the Artillery Ruby (Marlin's MARLIN_ARTILLERY_RUBY variant). For recovery without a working firmware: the board's BOOT0 jumper. |
Settings commands (ports, backup-settings, restore-settings,
versions) only need the first three rows. To choose a flashing tool, pass
--programmer with the path of dfu-util.exe or STM32_Programmer_CLI.exe.
PlatformIO\Marlin\ <- search folder for firmware
├── ArtilleryRubyTools\ <- this project
│ ├── update_printer.py <- one-step update script
│ ├── src\ruby_tools\ <- ruby-tools package
│ ├── tests\
│ ├── backups\ <- created on first use
│ │ ├── settings-<time>.gcode <- settings backups (M503)
│ │ └── flash-<time>.bin <- complete flash backups
│ └── .venv\ <- created by the setup below
├── Marlin-2.1.2.9\ <- a Marlin source folder (any name)
│ ├── platformio.ini <- with ini\*.ini: defines [env:Artillery_Ruby]
│ ├── ini\*.ini
│ ├── Marlin\Configuration.h
│ ├── Marlin\Configuration_adv.h
│ └── .pio\build\Artillery_Ruby\firmware.elf <- build output, flashed
├── Marlin-2.1.3\ <- more source folders: you choose
└── MarlinBuilds\ <- optional: prebuilt firmware
└── builds\Artillery\Hornet\
└── Artillery_Ruby\ <- PlatformIO environment
├── firmware.zip <- contains firmware.bin
└── firmware.bin.sha256.txt
- Marlin sources are found in the folder that contains this project. A
folder counts if it has
platformio.ini,Marlin\Configuration.hand the PlatformIO environment; its name does not matter. Elsewhere, pass--marlin-dir(update_printer.py) or--search-dir(versions). - Prebuilt firmware comes from a clone of
MarlinBuilds in the same
folder:
git clone https://github.com/MarlinFirmware/MarlinBuilds.git. A folder counts if it has abuilds\folder; prebuilt firmware is found atbuilds\<vendor>\<model>\...\<environment>\firmware.zip. Update it withgit pull. These builds use Marlin's example configuration for the printer, not your own configuration. - Backups:
update_printer.pyalways writes toArtilleryRubyTools\backups\.ruby-toolsusesbackups\in the current folder, so run it fromArtilleryRubyTools, or pass--backup-dir/--output. - From a Marlin source,
firmware.elfis flashed. Prebuilt firmware is flashed from itsfirmware.zip.
From the ArtilleryRubyTools folder in PowerShell:
py -3.12 -m venv .venv
.\.venv\Scripts\Activate.ps1
python -m pip install -e .ruby-tools is then available while the .venv is active.
update_printer.py also works without activating it: started with any
Python 3, it restarts itself with the .venv Python.
All commands find the printer by themselves: each USB serial port is opened
and asked for M115, and the one that answers as Marlin is used. If no port or
several ports answer, the ports are listed and you are asked to pick one, by
number or name. A port another program holds open (Pronterface, a slicer) is
shown as "in use". To skip the search, pass --port COM5.
ruby-tools portslists all serial ports and which of them answer as a Marlin printer.
Ask Marlin to report its settings with M503:
ruby-tools backup-settingsThe backup is written under backups\ as a .gcode file. Choose another
location with --output. The saved file contains only recognized setting
commands from the M503 response and can be inspected before restoring.
ruby-tools restore-settings --input .\backups\settings-YYYYMMDD-HHMMSS.gcodeRestore requires an interactive yes confirmation unless --yes is supplied.
Only the setting commands supported by this tool are sent; motion, heater, and
other unrecognized G-code is rejected. If the printer ignores a setting, the
restore stops before saving anything. The exception is input shaping (M593):
if the connected firmware was built without it, those lines are skipped with a
warning and the rest is restored. By default, settings are applied to
RAM only. Add --save to send M500 after all settings have been accepted by
the printer and persist them to EEPROM.
Keep the printer idle while using the serial connection. Close slicers and other programs that may already be using the selected port. Verify that a backup belongs to the connected printer and firmware before restoring it.
Marlin's M997 restarts the Artillery Ruby board into the STM32 chip's
built-in DFU bootloader. dfu-util or STM32CubeProgrammer then writes the
firmware over USB. The DFU bootloader is in read-only system memory, so a
failed write can always be repeated.
python update_printer.pyThe script checks, before anything is changed:
ruby-toolsand a flashing tool are installed: dfu-util from PlatformIO, otherwise STM32CubeProgrammer.- For a Marlin source:
firmware.elfexists and is newer thanConfiguration.handConfiguration_adv.h. If not, it is built with PlatformIO; without PlatformIO, the script stops.--buildalways builds. - For prebuilt firmware:
firmware.zipcontains onefirmware.binwhose SHA-256 checksum matchesfirmware.bin.sha256.txt. - The serial port exists if
--portis given.
Then it runs ruby-tools update-firmware, which stops at the first failed
check:
- Checks the firmware file (
.elf,.binor.zip): starts at0x08000000, fits in flash, valid start-up code, contains a Marlin version and machine type. - Checks that no board is already in DFU mode, the printer answers
M115, reports the same machine type as the firmware, and is not printing (M27). - Backs up the settings (
M503) tobackups\settings-<time>.gcode. - Asks for
yes(skip with--yes). - Restarts the board into DFU mode (
M997) and backs up the complete flash tobackups\flash-<time>.bin. If this fails, the old firmware is started again. - Writes the firmware, reads it back and compares it. If this fails, the board stays in DFU mode and the error says how to write the backup back.
- Starts the firmware and checks that
M115reports exactly the new build. - Restores the settings, saves them with
M500, reloads them withM501and checks them.
The script first asks the printer for its machine type (e.g. Hornet), then
lists the firmware to choose from (see Folder layout):
- Marlin sources with the PlatformIO environment (
[env:Artillery_Ruby]), newest configuration first; built if needed. - Prebuilt firmware from MarlinBuilds for that environment and for the printer's machine type. If the printer does not answer, prebuilt firmware of all machine types is listed; the update still refuses firmware for another machine type.
With one choice, it is used. With several, you choose; Enter takes the first.
--marlin-dir or --firmware choose directly:
python update_printer.py --marlin-dir ..\Marlin-2.1.2.9
python update_printer.py --firmware ..\MarlinBuilds\builds\Artillery\Hornet\Artillery_Ruby\firmware.zipPrinter on COM3: Hornet
Firmware for Hornet with the environment 'Artillery_Ruby':
1) Marlin-2.1.2.9 - source, Marlin 2.1.2.9, configuration changed 2026-11-01 14:02
2) Marlin-2.1.2.5 - source, Marlin bugfix-2.1.x, configuration changed 2024-12-27 16:49
3) MarlinBuilds: Artillery/Hornet - prebuilt, Marlin 2.1.2.8 (Jun 25 2026 00:25:43), machine Hornet
Enter the number of the firmware to flash [1]:
Script options: --port (default: detect the printer), --marlin-dir or
--firmware (default: choose as above), --environment (default
Artillery_Ruby), --programmer, --build (Marlin sources only), and
--restore-settings:
auto(default): restore the settings backup from step 3.none: keep the settings the new firmware starts with.- a file: restore that backup, e.g. one where you removed lines whose new firmware defaults you want to keep.
The script runs with any Python 3: if ruby-tools cannot be imported, it
restarts itself with the project's .venv Python.
Firmware files and the settings sector:
.elf(PlatformIO build): carries its own addresses and only the parts of the firmware, so the emulated EEPROM sector (0x08004000) with the stored settings is not touched..bin(PlatformIO build) and.zip(MarlinBuilds): a raw image from0x08000000that also covers the settings sector, filled with0x00or0xFF. The tools leave out 16 KB blocks in the first 64 KB that contain only such fill bytes, so the settings sector is not erased either.
Prebuilt firmware is built with Marlin's example configuration. Features you
enabled in your own build (e.g. input shaping, the input shaping menu,
leveling after G28) may be missing; restoring settings skips input shaping
values if the firmware has no input shaping.
A firmware with a different settings layout starts with default settings even though the sector is not erased. That is why settings are restored by default.
dfu-util has no verify step and erases a flash sector before its first write in
each run. The tools therefore write parts of the .elf that share a sector in
one run, and read every written range back to compare it.
ruby-tools versions --printerlists the firmware that can be flashed:
- Marlin sources next to this project with the PlatformIO environment,
newest configuration first: Marlin version, configuration date, and the
build in
.pio\build\<environment>\firmware.elfwith its version, or why it is missing or outdated. - Prebuilt firmware from MarlinBuilds for the environment, with version, machine type and path; damaged downloads (checksum mismatch) are marked.
- Flash backups in
backups\with the firmware they contain; they can be written back withrestore-flash.
--printer (or --port) also asks the printer which firmware it runs and
marks the matching build and backups, and the prebuilt firmware for its
machine type. Other options: --environment,
--search-dir (default: the folder that contains this project) and
--backup-dir.
Printer on COM3: Hornet, Marlin 2.1.2.9 (Nov 1 2026 14:03:38)
Marlin sources in C:\...\PlatformIO\Marlin (environment Artillery_Ruby):
Marlin-2.1.2.9: Marlin 2.1.2.9, configuration changed 2026-11-01 14:02
build: Marlin 2.1.2.9 (Nov 1 2026 14:03:38), up to date <- on the printer
Marlin-2.1.2.5: Marlin bugfix-2.1.x, configuration changed 2024-12-27 16:49
build: not built
Prebuilt firmware in C:\...\PlatformIO\Marlin (environment Artillery_Ruby):
MarlinBuilds: Artillery/Genius Pro: Marlin 2.1.2.8 (Jun 25 2026 00:26:45), machine Genius Pro
C:\...\MarlinBuilds\builds\Artillery\Genius Pro\Artillery_Ruby\firmware.zip
MarlinBuilds: Artillery/Hornet: Marlin 2.1.2.8 (Jun 25 2026 00:25:43), machine Hornet <- for this printer
C:\...\MarlinBuilds\builds\Artillery\Hornet\Artillery_Ruby\firmware.zip
MarlinBuilds: Artillery/Sidewinder X2: Marlin 2.1.2.8 (Jun 25 2026 00:26:25), machine Sidewinder X2
C:\...\MarlinBuilds\builds\Artillery\Sidewinder X2\Artillery_Ruby\firmware.zip
Flash backups in C:\...\ArtilleryRubyTools\backups (restore with restore-flash):
flash-20261101-155254.bin: Marlin 2.1.2.9 (Nov 1 2026 14:03:38) <- on the printer
factory-flash-2026-11-01.bin: Marlin bugfix-2.1.x (Dec 29 2024 19:03:52)
ruby-tools update-firmware `
--firmware ..\Marlin-<version>\.pio\build\Artillery_Ruby\firmware.elf `
--restore-settings
ruby-tools update-firmware `
--firmware ..\MarlinBuilds\builds\Artillery\Hornet\Artillery_Ruby\firmware.zip `
--restore-settings
ruby-tools backup-flash
ruby-tools restore-flash --input .\backups\flash-YYYYMMDD-HHMMSS.bin--restore-settingswithout a file restores the backup made at the start; with a file, that backup. Leave it out to keep the new firmware's settings.backup-flashsaves the complete flash and starts the unchanged firmware again.restore-flashwrites a complete flash backup back, e.g. to return to the previous firmware. If the board is already in DFU mode, no serial port is needed; otherwise the printer is found as usual.- After flashing,
update-firmwarealso finds the printer if Windows gave it a new COM port.
If the board does not start after a failed update, it cannot be switched into
DFU mode with M997. Run the same update again if it is still in DFU mode
(dfu-util -l or STM32_Programmer_CLI -l usb lists it). Otherwise, put it into DFU mode with
the board's BOOT0 jumper, run ruby-tools restore-flash --input <flash backup>, then remove the jumper.
The tests use Python's standard unittest runner:
python -m unittest discover -s tests -vCode checks with flake8 and pylint, installed with the dev extra:
python -m pip install -e ".[dev]"
python -m flake8
python -m pylint src/ruby_tools tests update_printer.pyBoth use lines up to 100 characters. flake8 is configured in .flake8
(it cannot read pyproject.toml), pylint in pyproject.toml. flake8 ignores
E203 (spaces around : in slices, as PEP 8 allows for complex slices).
pylint asks for docstrings only on functions and classes longer than 10 lines;
the test files switch off messages that do not apply to tests in their
header comment.
All files use LF line endings; .gitattributes keeps it that way.