Developed with Plugwise Emma in mind. Mix source climates (
current_temperatureandtemperature) with numerical heating-demand delta sensors in °C. Destinations may expose either a singletemperaturetarget or atarget_temp_low/target_temp_highrange.
Demand thresholds now accept 0.001 °C steps, with an activation minimum of 0.001 °C. Defaults stay at 0.3 °C activation / 0.1 °C deactivation. For precise external demand sensors, a small positive activation threshold and zero deactivation can distinguish a tiny active request from zero source demand. For example, a 0.030 °C source delta is active with a 0.001 °C threshold, yet rounds a 20.3 °C destination reading back to a 20.3 °C target. With no source demand, the configured fixed or relative idle policy applies. A target equal to current temperature does not guarantee zero device heating power. No automatic change to existing thresholds, sources, or idle settings.
Choose Setback target (fixed idle temperature) or Setback delta (current destination temperature minus setback), followed by one numeric field with a 0.5 °C input step. Delta accepts zero. Target uses the destination minimum; all computed targets respect the destination limits and configured maximum. When relative mode lacks a current temperature, it falls back to the advertised minimum and exposes that fallback in diagnostics. Delta 0 is a target equal to current temperature, not a command guaranteeing zero boiler demand. Existing installations migrate to fixed target mode with their effective value unchanged. Sources, hysteresis and update safeguards are preserved.
The minimum destination change is inclusive: a configured 0.1 °C change sends both upward and downward steps of exactly 0.1 °C, with tolerance for decimal floating-point representation. Identical targets remain quiet, even with a zero minimum. Mismatch tracking uses the same decision as delivery. Source selection, demand hysteresis, rounding and rate limiting are unchanged.
Climate sources and numerical delta sensors can now be used together, or either type on its own. Both feed the same maximum-delta calculation and primary-source selection. Missing or invalid inputs contribute zero without blocking healthy rooms. Existing source selections, hysteresis, rounding, rate limiting and destination control remain unchanged; no room switches to a new source automatically. PI-to-delta conversion remains in external helpers, not in ClimateSync.
This release adds a downloadable Home Assistant diagnostics file. It captures the configured source and destination roles, current source health and deltas, demand state, setpoint calculation, timestamps, counters, and the latest error. It contains no credentials and does not change ClimateSync's control behaviour.
This release adds two first-class heating-demand binary sensors. Heating Demand Active follows all configured sources, while Primary Heating Demand Active follows only the user-selected primary subset. Both use the exact same configured activation and deactivation thresholds; the primary scope does not change destination control. The setup and options flows are now a documented five-step wizard with Next buttons between steps and Submit only on the final step.
This release retains the clearer source-health diagnostics from 1.2.4 while restoring the active idle fallback when no usable source remains. That fail-safe withdraws a potentially stale heating request instead of leaving the last destination target untouched.
This release makes partial source failures explicit and safe. A source climate
that is off but still exposes a valid current temperature is treated as a
usable inactive room with zero heating demand. Unavailable or incomplete
sources are reported as degraded_source_data, while healthy rooms continue to
drive the destination. ClimateSync suppresses destination writes only when no
usable source remains.
This release adds configurable heating-demand hysteresis. Small positive room
deltas no longer start the destination thermostat immediately; by default,
demand starts at 0.3 °C and stops at 0.1 °C. The existing destination-setpoint
anti-flap and rounding behaviour remain unchanged.
Heating range destinations are supported by controlling target_temp_low while
preserving their current target_temp_high atomically.
ClimateSync is a HACS-ready Home Assistant custom integration that implements delta-based thermostat synchronisation. It reads heating demand from source climates (target minus current temperature) and/or already calculated numerical delta sensors, then drives a single destination thermostat by continuously adjusting its target temperature.
Instead of simply syncing the highest source setpoint to the destination, ClimateSync uses the maximum delta (largest gap between target and current temperature across all rooms) and adds it to the destination's own current temperature:
destination_target = destination_current_temperature + delta_max
This approach was designed with the Plugwise Emma in mind. The Emma is connected to the central-heating boiler (CV) over OpenTherm and internally calculates a desired CV water temperature based on its own current delta. By feeding the Emma the home-wide maximum delta on top of its own measured temperature, ClimateSync lets the Emma function as a full OpenTherm controller — it sees the "hardest working" room's demand and adjusts the boiler modulation accordingly.
Even without an Emma, this delta-based method is more accurate than copying setpoints because it accounts for how far the destination already is from equilibrium.
- Event-driven updates — reacts immediately to temperature changes.
- Mixed sources: climate entities and explicit numerical delta sensors in °C.
- Periodic resync (configurable, default 60 s) to recover from missed events.
- Anti-flap: only sends
climate.set_temperaturewhen a nonzero change reaches a configurable minimum (default 0.2 °C). - Configurable demand hysteresis: start heating at 0.3 °C room delta and stop at 0.1 °C by default.
- All-source and primary-source heating-demand binary sensors, both driven by the configured hysteresis.
- Destination target selection: ordinary
temperature(default) or heating-rangetarget_temp_low. - Rate limiting: maximum one service call per 10 seconds (configurable).
- Rich diagnostic sensors plus a downloadable diagnostics file for support and troubleshooting.
- No controllable entities — all control is internal via
climate.set_temperature.
- Open HACS → Integrations → ⋮ → Custom repositories.
- Add
https://github.com/Patrick1610/ClimateSyncas an Integration. - Search for ClimateSync and install.
- Restart Home Assistant.
- Copy
custom_components/climatesync/to your<config>/custom_components/directory. - Restart Home Assistant.
Navigate to Settings → Devices & Services → Add Integration → ClimateSync.
Choose either or both fields; together they must contain at least one source:
- Source climate entities: existing room thermostats exposing
current_temperatureandtemperature. Their contribution remainsmax(target - current, 0); anoffclimate contributes zero. - Heating-demand delta sensors (°C): sensors whose numeric state is already the required heating gap in Celsius. For example, an external helper can translate 20 percentage points of raw PI demand × 0.03 °C per percentage point into 0.60 °C. Select that helper, not the raw percentage sensor or a room temperature sensor. ClimateSync does not perform PI conversion or phase selection.
The highest delta wins, not the sum. A mixture of 0.60 °C from a PI helper, 0.40 °C from an office climate and 0.25 °C from a bathroom climate produces 0.60 °C. With the destination measuring 20.3 °C, its raw target is 20.9 °C. Normal demand thresholds, rounding and limits still apply.
Missing, unknown, unavailable, nonnumeric or non-finite delta values contribute
zero. A delta sensor must report unit_of_measurement: °C; other or missing units
are also treated as invalid zero demand. Healthy sources continue to drive the
destination, with existing source-health diagnostics showing the failed sources.
If all sources fail, ClimateSync withdraws demand using the existing idle fallback.
Move one room at a time: select its delta helper and remove that room's old climate sources from ClimateSync. Leaving both selected can let the old temperature gap overrule PI modulation. Other rooms can stay on climate sources. Review the room's primary-source role in step 2. No source, primary role or setting is replaced automatically by an upgrade. Do not select ClimateSync's own calculated output sensors as inputs, which would create a feedback loop.
The primary-source checkboxes show Home Assistant display names while retaining entity IDs internally. Missing names fall back to the entity ID; duplicate names include the ID for disambiguation. Opening or saving the wizard does not change source identities or their existing primary/secondary role just because labels changed. This applies to both climate and delta-sensor sources.
Select the subset of sources (climates and/or delta sensors) that may enable other rooms to piggyback on
an existing heating run. General destination control still uses all sources.
A secondary room can therefore start heating when it falls below its own target,
but it does not turn on Primary Heating Demand Active.
Existing installations migrate with every existing source selected as primary, so the upgrade does not silently narrow their demand scope.
| Field | Default | Description |
|---|---|---|
| Destination climate entity | — | The thermostat that ClimateSync will control. |
| Destination target | Target temperature | Select ordinary temperature or lower target target_temp_low for a heating range climate. |
| Setback mode | Setback target | Fixed idle target, or current destination temperature minus a non-negative setback. |
| Maximum setpoint | 35.0 °C | Hard ceiling for the destination setpoint. |
| Rounding mode | 1 decimal | Step size used for the computed setpoint. |
| Rounding direction | nearest | Whether the computed setpoint is rounded down, normally, or up within the selected rounding mode. |
In Setback target mode, enter the fixed idle target (default 5 °C, bounded by the selected destination's minimum/maximum and configured ceiling). In Setback delta mode, enter the reduction (minimum 0 °C, default 0). Both use a 0.5 °C input step. At a measured 20.7 °C, setback 10 requests 10.7 °C and setback 0 requests 20.7 °C, before rounding and device limits. A zero delta does not guarantee zero device heat demand. If the relative mode has no valid current reading, ClimateSync requests the device minimum; if even that is unavailable it reports destination unavailable without sending an invalid target.
| Option | Default | Description |
|---|---|---|
| Resync interval | 60 s | How often ClimateSync checks even without state changes. |
| Minimum destination change | 0.2 °C | Send a changed destination setpoint when the difference reaches this minimum. It does not determine demand state. |
| Heating-demand activation threshold | 0.3 °C | Delta required to switch either demand scope on. |
| Heating-demand deactivation threshold | 0.1 °C | Delta at or below which an active demand scope switches off. Must be lower than activation. |
| Minimum send interval | 10 s | At most one destination service call per this many seconds. |
After setup, open the integration → Configure (⚙ gear icon) to get the same five-step wizard again. Intermediate steps show Next; only the final step shows Submit. You can change:
- Step 1: add or remove source rooms;
- Step 2: choose the primary subset;
- Step 3: change destination and setpoint behaviour;
- Step 4: set the fixed target or relative setback;
- Step 5: change hysteresis, resync, anti-flap, and rate limiting.
| Option | Default | Description |
|---|---|---|
| Destination thermostat | — | Change which thermostat is controlled. |
| Destination target | Target temperature | Select ordinary temperature or lower target target_temp_low for a heating range climate. |
| Idle temperature | 5.0 °C | Temperature sent when no room needs heating. |
| Maximum setpoint | 35.0 °C | Hard ceiling for the destination setpoint. |
| Rounding mode | 1 decimal | Step size used for setpoints. |
| Rounding direction | nearest | floor, nearest, or ceiling rounding within the selected mode. |
| Resync interval | 60 s | How often ClimateSync checks even without state changes. |
| Minimum change threshold | 0.2 °C | Send a changed setpoint when the difference reaches this minimum. |
| Heating-demand activation threshold | 0.3 °C | Minimum room delta required to activate the destination thermostat. |
| Heating-demand deactivation threshold | 0.1 °C | Delta at or below which active heating demand stops. Must be lower than the activation threshold. |
| Minimum send interval | 10 s | At most one service call per this many seconds. |
For each source climate entity (room):
current = current_temperature attribute
target = temperature attribute
if state == off and current is valid:
source is usable but inactive; delta = 0
elif current or target is missing/unavailable:
source is degraded; delta = 0
else:
source is active; delta = max(target - current, 0)
For each selected numerical delta sensor:
if state is missing, invalid, non-finite, or unit is not °C:
source is degraded; delta = 0
else:
source is usable; delta = max(numeric state, 0)
If no usable source remains:
apply the configured idle policy instead of the previous active demand
delta_max = max(all room deltas)
If demand is inactive and delta_max >= demand_activation_threshold:
demand becomes active
If demand is active and delta_max <= demand_deactivation_threshold:
demand becomes inactive
primary_delta_max = max(deltas of configured primary sources)
Apply the same activation/deactivation hysteresis independently to
primary_delta_max to calculate primary_demand_active
If demand is inactive:
setpoint_raw = idle_value if idle_mode == target else destination_current_temperature - idle_value
Else:
setpoint_raw = destination_current_temperature + delta_max
# The destination target is set to its own current temperature
# plus the largest demand across all source rooms. This means the
# destination "feels" the same heating gap as the hardest-working
# room, which is critical for OpenTherm controllers like the
# Plugwise Emma that modulate boiler output based on their own
# observed delta.
rounded_setpoint = round_setpoint(setpoint_raw, rounding_mode, rounding_direction)
setpoint_final = min(rounded_setpoint, maximum_setpoint)
If the target changed AND abs(destination_current_target - setpoint_final) >= min_change_threshold:
If time_since_last_call >= min_send_interval:
If destination_target == temperature:
climate.set_temperature(destination, temperature=setpoint_final)
Else:
climate.set_temperature(
destination,
target_temp_low=min(setpoint_final, current_target_temp_high),
target_temp_high=current_target_temp_high,
)
Home Assistant requires both range bounds in the same set_temperature action.
ClimateSync therefore reads the upper target again immediately before applying a
lower target, preserves it in the same action, and never controls cooling through
target_temp_high.
The rounding mode determines the step size. The rounding direction determines where the raw setpoint lands within that step size. ClimateSync applies epsilon-safe floor/nearest/ceiling rounding to avoid floating-point edge cases around step boundaries.
nearest is the default and preserves the historical ClimateSync behaviour for existing installations. If an older config entry does not contain rounding_direction, ClimateSync treats it as nearest.
| Mode | Example input | Result |
|---|---|---|
0.5 steps |
19.3 | 19.5 |
1 decimal |
19.33 | 19.3 |
2 decimals |
19.333 | 19.33 |
| Direction | Behaviour |
|---|---|
floor |
Always round down within the selected mode. |
nearest |
Round to the nearest step, matching the old behaviour. |
ceiling |
Always round up within the selected mode. |
Plugwise Emma examples:
| Mode + direction | Raw setpoint | Sent setpoint |
|---|---|---|
0.5 steps + ceiling |
19.1 | 19.5 |
0.5 steps + ceiling |
19.5 | 19.5 |
0.5 steps + ceiling |
19.6 | 20.0 |
0.5 steps + floor |
19.1 | 19.0 |
0.5 steps + floor |
19.9 | 19.5 |
1 decimal + ceiling |
19.11 | 19.2 |
1 decimal + floor |
19.19 | 19.1 |
For Plugwise Emma, 0.5 steps can be useful because Emma commonly accepts half-degree setpoints. Combining 0.5 steps with ceiling can help when small RoomMind deltas would otherwise disappear through normal rounding, for example a raw setpoint of 19.1 becoming 19.5 instead of 19.0.
All entities are attached to a ClimateSync device. Sensors (setpoint, deltas, destination target) are regular entities; the status sensor is classified as diagnostic. Home Assistant can also download a diagnostics file from the integration or device page.
Logical regulation demand across all configured sources. It switches on at the configured activation threshold and remains on until the maximum delta reaches the configured deactivation threshold. It means ClimateSync has a qualified heating request; it does not prove that the boiler is physically firing or that the destination accepted the last write.
The same independently retained hysteresis state, calculated only over the configured primary subset. Use this entity to enable secondary rooms to piggyback without allowing those secondary rooms to trigger one another. It is unavailable when none of the configured primary sources has usable data.
Both entities expose their scope, current maximum delta, leading source, thresholds, source list, and source-health diagnostics as attributes.
| Attribute | Description |
|---|---|
destination_entity_id |
The controlled thermostat |
destination_target |
Selected destination target: temperature or target_temp_low |
destination_current_temperature |
Current measured temperature at destination |
destination_current_target |
Current target temperature at destination |
delta_max |
Max delta used for this computation |
demand_active |
Whether the hysteresis currently considers heating demand active |
demand_activation_threshold |
Configured room delta required to start demand |
demand_deactivation_threshold |
Configured room delta at or below which demand stops |
rounding_mode |
Active rounding mode |
rounding_direction |
Active rounding direction |
raw_setpoint |
Unrounded destination_current_temperature + delta_max, or idle temperature when no room needs heating |
rounded_setpoint |
Raw setpoint after rounding mode and rounding direction |
final_setpoint |
Final setpoint after rounding and maximum-setpoint clamp |
idle_temperature |
Absolute idle temperature (legacy attribute) |
idle_mode / idle_value |
Configured fixed target or relative reduction |
idle_setpoint |
Calculated absolute idle target before rounding and limits |
idle_fallback_active |
Relative mode lacks current temperature and uses the device minimum |
State: the final setpoint that ClimateSync wants to apply (destination_current_temperature + delta_max, rounded and capped by maximum setpoint).
| Attribute | Description |
|---|---|
room_deltas |
Map of {entity_id: delta} for all rooms |
leading_room |
Entity id of the room with the highest delta |
usable_source_count |
Number of sources that can safely participate |
degraded_source_entities |
Unavailable or incomplete sources ignored for demand |
inactive_source_entities |
off sources with a valid measurement and zero demand |
State: the maximum delta across all rooms.
One sensor per configured source, climate or numerical delta sensor.
| Attribute | Description |
|---|---|
source_entity_id |
The source entity this sensor tracks |
current_temperature |
Current temperature for a climate; null for a delta sensor |
target_temperature |
Target temperature for a climate; null for a delta sensor |
raw_delta |
target - current, or the numeric delta sensor state (may be negative) |
source_status |
active, inactive_off, unavailable, missing_temperature, invalid_delta, or invalid_delta_unit |
State: max(raw_delta, 0) — the effective heating demand for this room.
Shows the destination thermostat's actual current target temperature in real time, making it easy to compare against the computed setpoint without switching to the destination device.
| Attribute | Description |
|---|---|
destination_entity_id |
The controlled thermostat |
destination_current_temperature |
Current measured temperature at destination |
State: the destination's current temperature attribute (its active target).
States:
| State | Meaning |
|---|---|
ok |
Everything is in sync, no issues. |
rate_limited |
A setpoint update was suppressed because the last call was too recent. |
destination_unavailable |
The destination climate entity is unavailable or unknown. |
degraded_source_data |
One or more sources are unavailable or incomplete, but at least one usable source remains. Valid rooms continue to control the destination. |
missing_source_data |
No usable source remains. ClimateSync applies the configured idle fallback until a source recovers. |
apply_failed |
The climate.set_temperature service call threw an exception. Check last_error. |
mismatch |
The destination's actual target deviates from the desired setpoint beyond the threshold. ClimateSync will attempt to correct this on the next cycle. |
Attributes:
| Attribute | Description |
|---|---|
last_update_time |
ISO timestamp of the last evaluation |
last_service_call_time |
ISO timestamp of the last climate.set_temperature call |
last_desired_setpoint |
What ClimateSync computed as the ideal setpoint |
last_applied_setpoint |
What was last actually sent to the destination |
current_destination_target |
The destination's actual temperature attribute right now |
rounding_mode |
Active rounding mode |
rounding_direction |
Active rounding direction |
raw_setpoint |
Last unrounded setpoint |
rounded_setpoint |
Last rounded setpoint before maximum-setpoint clamp |
final_setpoint |
Last final setpoint after rounding and clamp |
mismatch_seconds |
How long (seconds) the desired and actual setpoint have been diverging |
mismatch_since |
ISO timestamp of when the mismatch started (null when in sync) |
resync_count |
Number of periodic resyncs since startup |
apply_attempts |
Total service call attempts since startup |
apply_failures |
Total service call failures since startup |
evaluation_count |
Total evaluation cycles since startup |
skipped_anti_flap |
Times a setpoint update was skipped because the change was within the threshold |
skipped_rate_limit |
Times a setpoint update was skipped due to rate limiting |
last_error |
Last exception message, if any |
source_count |
Number of configured climate and delta-sensor sources |
usable_source_count |
Number of sources currently safe to use |
degraded_source_entities |
Sources currently ignored because data is unavailable or incomplete |
inactive_source_entities |
off sources that remain valid measurements with zero demand |
Some thermostats (e.g. Plugwise Emma) only accept specific temperature steps. Use the 0.5 steps rounding mode in that case. If small RoomMind deltas are rounded away, use Rounding direction = ceiling so a raw setpoint such as 19.1 is sent as 19.5 instead of 19.0.
An external automation or the user may be overriding the destination's target. ClimateSync will keep trying to reapply on every evaluation cycle and resync. Check if another integration or automation is fighting over the thermostat.
The source rooms are changing temperature very rapidly. Increase min_send_interval in the Options Flow to reduce chatter.
No selected source currently provides usable data. ClimateSync actively applies
the configured idle temperature so an earlier heating request cannot remain in
effect. Restore at least one source with a valid current_temperature and
temperature, an off source with a valid current_temperature, or a finite
numerical delta sensor with a °C unit.
At least one source is unavailable or lacks a required temperature attribute.
Other usable rooms continue to be processed. Inspect degraded_source_entities
and each delta sensor's source_status attribute.
The destination thermostat is offline. No service calls are made. ClimateSync will recover automatically once the entity becomes available again.
Check last_error in the sensor.climatesync_status attributes. Most likely the climate entity does not support the climate.set_temperature service or the entity id is wrong.
ClimateSync uses only the standard climate.set_temperature service. It reads standard source climate attributes (current_temperature, temperature) and/or numerical heating-demand delta sensors in °C. Delta sensors remain read-only inputs; ClimateSync never writes them. It works with any climate integration that follows the standard HA climate platform contract, including but not limited to:
- Plugwise Emma / Smile
- Generic Thermostat
- ESPHome climate components
- Z-Wave thermostats
- Zigbee thermostats (ZHA / Zigbee2MQTT)
- Google Nest (via the Nest integration)
The coordinator, entities, diagnostics and setup/options wizard have isolated
unit tests. Install pytest, pytest-asyncio and voluptuous, then run:
PYTEST_DISABLE_PLUGIN_AUTOLOAD=1 python -m pytest -p pytest_asyncio.plugin -qOnly the asyncio plugin is enabled explicitly so unrelated Home Assistant test plugins in a shared environment cannot change these unit tests. GitHub Actions runs the same suite, plus the existing hassfest and HACS validation workflows.
MIT — see LICENSE.