Skip to content

feat(battery): opt-in eFuse-calibrated ADC read for ESP32 battery sense - #184

Open
gcormier wants to merge 3 commits into
OpenDisplay:mainfrom
gcormier:feat/esp32-adc-calibrated-battery
Open

gcormier wants to merge 3 commits into
OpenDisplay:mainfrom
gcormier:feat/esp32-adc-calibrated-battery

Conversation

@gcormier

@gcormier gcormier commented Nov 11, 2026 •

Copy link
Copy Markdown
Contributor

Adds an opt-in way for ESP32 boards to read the battery-sense pin with the chip's eFuse ADC calibration (analogReadMilliVolts()), so one voltage_scaling_factor fits every board of a model.

Today the battery voltage is raw_count * voltage_scaling_factor / 100000. Raw ESP32 ADC counts vary a few percent from chip to chip, so a factor tuned on one board reads off on the next. Two original M5Papers with the same preset (factor 174) read 4.20 V and 4.10 V for full cells.

Changes

  • include/opendisplay_structs.h: new OD_BATTERY_SENSE_FLAG_CALIBRATED_MV (bit 1 of PowerOption.battery_sense_flags, carved from reserved; no layout change). With the bit set, voltage_scaling_factor is the divider ratio x1000 and V = calibrated_pin_mV * factor / 1e6 (2000 = 2:1). With the bit clear, the formula is unchanged. Changelog entry under Unreleased. This still needs to land in opendisplay-protocol.
  • src/display_service.cpp (readBatteryVoltageUncached()): with the bit set on ESP32, the 10 samples use analogReadMilliVolts(). Same sample count, delays and 30 s cache. On non-ESP32 targets the bit makes the voltage "unknown" (-1) with a one-time warning, rather than applying a x1000 ratio to a raw count. A zero factor now returns -1 before pulsing the enable pin; same result as before.
  • src/config_parser.cpp: the config dump prints the new bit.
  • tools/od-device-cli.py: comments only (the field is a plain u8).
  • docs/FINDINGS_ESP32_ADC_CALIBRATED_2026-11-11.md: the hardware A/B below. Drop it if you'd rather not keep it in the repo.

Why a flag instead of changing what the factor means: every deployed config and every toolbox preset holds a factor tuned for raw counts. The firmware cannot tell which unit a stored factor is in, so a silent switch would break the battery reading of every ESP32 board (174 under the new formula is ~0.4 V).

Order of rollout: firmware that predates this ignores the bit, so a calibrated config on old firmware reads ~48 V. The toolbox preset change (M5Paper: battery_sense_flags 0x2, voltage_scaling_factor 1999) should only ship after a release that contains this.

Testing

Hardware: one original M5Paper (ESP32-D0WDQ6-V3, GPIO35 through a 2:1 divider), A/B by switching the config over BLE.

  • On battery, charger out of the loop, cell 3-27 min off the charger: calibrated (factor 1999) 4.20, 4.19, 4.20 V; legacy (factor 174) 4.11, 4.10, 4.11, 4.10 V; calibrated again 4.19 V. The bracket rules out cell drift.
  • On USB after charging: calibrated 4.23-4.24 V, legacy 4.13 V.
  • Factor 1999 comes from a second M5Paper: 2101 mV at the pin (calibrated read) for a 4.20 V cell.
  • All 12 CI targets build.

Not tested:

  • Against a multimeter.
  • Lower in the discharge curve (3.3-3.8 V).
  • ESP32-S3/C3/C6 (different calibration schemes) and any board other than the M5Paper.
  • The first reading after a boot is sometimes high (seen with both paths, clears at the next 30 s refresh); not investigated.

Found while doing this, not fixed here: OD_BATTERY_SENSE_FLAG_ENABLE_INVERTED (bit 0) is only logged. readBatteryVoltageUncached() always drives the enable pin HIGH then LOW, so active-low enables (e.g. XIAO ~READ_BAT) are not honoured.

Toolbox preset (draft until this ships in a release): OpenDisplay/opendisplay.org#207

Raw ESP32 ADC counts vary several percent chip to chip, so one
voltage_scaling_factor cannot fit every board of a model (two M5Papers on
the same factor read 4.20 V vs up to 4.33 V on USB).

Add BatterySenseFlags bit1 OD_BATTERY_SENSE_FLAG_CALIBRATED_MV. When set,
ESP32 reads the sense pin with analogReadMilliVolts() (core eFuse
calibration) and voltage_scaling_factor is the divider ratio x1000:
V = mV * factor / 1e6 (2000 = 2:1). When clear, the legacy meaning
V = raw_count * factor / 1e5 is unchanged, so every deployed config reads
exactly as before. Non-ESP32 targets report the voltage as unknown (-1)
with a one-time warning if the bit is set. Sample count, delays and the
30 s cache are unchanged.

Also documents the bit in opendisplay_structs.h (Unreleased changelog,
field @doc), logs it in the config dump, and notes the two meanings in
tools/od-device-cli.py.

Builds clean on all 12 envs in .github/firmware-targets.json.
NOT verified on hardware: no device was flashed or measured.
Checked on one M5Paper (the bathroom board) on USB, comparing the calibrated and legacy paths via the advertised voltage: calibrated 4.23-4.24 V, legacy 4.13 V. NOT checked against a multimeter, so absolute accuracy is unverified.
With the charger out of the loop the calibrated path read 4.19-4.20 V and the legacy path 4.10-4.11 V on the same M5Paper, bracketed by switching methods over BLE. No multimeter reading.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment