Golden source for talking to Hitron HT-EM5 MoCA bridges, the CODA6X
(e.g. CODA-60) DOCSIS gateway REST API, and the CODA-57 legacy .asp
status API, plus an experimental, read-only CODA 4x8x client (CODA-4582,
CODA-4680; not verified on live hardware). One Python package, one set of OpenAPI specs, one metrics
exporter — meant to replace the three separate, unwired implementations that
otherwise accumulate (a standalone client with no consumer, a consumer with
no client, and an unversioned sidecar script next to the product that needs
it). See docs/KB.md for the full reverse-engineering writeup: every
endpoint, every auth scheme, firmware quirks, and open questions.
What is in the repo:
| Path | Contents |
|---|---|
specs/openapi-coda60.yaml |
Full CODA6X console API: 116 paths, 171 operations, every route in the firmware's routes.ini, auth branches, error envelope, request encoding, and the advanced OFDM/OFDMA/PNM fields. |
specs/openapi-ht-em5.yaml, specs/openapi-coda57-legacy.yaml |
The other two established device families. |
specs/openapi-coda4x8x.yaml |
Experimental, read-only CODA 4x8x description (31 reads plus login), generated from the same registry. Not verified on live hardware. |
src/hitron/metrics.py |
One normalized metric vocabulary for all three families. |
src/hitron/formats.py |
Prometheus, Influx/Telegraf, OTLP/HTTP JSON, and JSON encoders. |
src/hitron/exporter.py |
Multi-device poller with /metrics, /healthz, /api/v1/samples, /api/v1/logs, and OTLP push. |
dashboards/ + deploy/ |
Importable Grafana JSON and a one-command Prometheus/Grafana/Loki stack. |
cli/ |
Standalone Go hitron-cli: detection, live TUI, RF detail, and confirmed reset actions. No dependencies. |
site/ |
Build-free GitHub Pages docs: API console, live charts, logs. |
Guides: docs/GETTING-STARTED.md (end to end),
docs/GRAFANA.md (dashboards and alerts),
docs/KB.md (reverse-engineering notes), and
llms.txt (machine-readable summary for LLM tooling).
Devices this covers:
| Package | Device | API shape | Auth |
|---|---|---|---|
hitron.ht_em5 |
HT-EM5 (MoCA bridge) | POST /ms/{type}/{reg} register RPC |
HTTP Basic |
hitron.coda60 |
CODA6X (e.g. CODA-60) | /1/Device/... PHP+REST (TR-181 via cosa.so) |
Session cookie or JWT app token |
hitron.coda57 |
CODA-57 | GET /data/{endpoint}.asp legacy status API |
Unconfirmed (session-primed via /login.html) |
hitron.coda4x8x |
CODA 4x8x (CODA-4582, CODA-4680), experimental | Hypothesis: the CODA6X REST data model served from the site root, no /1/Device prefix. Read-only |
Unconfirmed (POST /Users/Login, GET /Users/CSRF) |
The CODA 4x8x row is experimental: not verified on live hardware. The route
list and login flow come from
hairyhenderson/hitron_coda (MIT);
only facts were used, no code. See docs/KB.md §4. It has no write or action
methods, by policy.
One line, no sudo, isolated virtualenv under ~/.local/share/hitron:
curl -fsSL https://hitron.netquor.dev/install.sh | bashIt links ~/.local/bin/hitron and hitron-exporter. Add -s -- --run to start
the local docs site and gateway proxy immediately. There is no PyPI
package: pip install hitron is an unrelated project.
Windows PowerShell 5.1 or newer uses the same install, with no admin rights:
& ([scriptblock]::Create((irm https://hitron.netquor.dev/install.ps1))) -RunDrop -Run to install without starting the site. Both installers keep
everything under the user profile and can be removed with --uninstall or
-Uninstall.
Manual install from a checkout:
python3 -m venv .venv && source .venv/bin/activate
pip install -e ".[dev]"See docs/LOCAL-PROXY.md for the one-liner, pipx/uv
equivalents, and troubleshooting.
Read (prints a JSON snapshot to stdout):
hitron ht-em5 192.168.0.212 --phy-rates
hitron coda60 192.168.100.1 # detect model, poll only what it supports
hitron coda60 192.168.100.1 --no-detect # poll every known endpoint
hitron coda60 192.168.100.1 --model coda60 # force a profile if detection is wrong
hitron coda57 192.168.100.1 --spec-check
hitron coda4x8x 192.168.0.1 # experimental, read-only; add --username/--password to log inModel catalog and read-only verification:
hitron coda60-models # every known profile + capability set
hitron coda60-models coda6011uv # one profile
hitron coda60-verify 192.168.100.1 --out verify.json
hitron coda60-verify 192.168.100.1 --model coda60 --group docsiscoda60-verify is GET-only and re-measures every endpoint in the resolved
profile's plan, including ones this firmware is known to break, so the report
is a current measurement rather than a restatement. The latest run against a
customer-owned CODA60 on 8.7.1.0.1b4 is in docs/VERIFICATION.md; the
machine-readable copy is specs/verification-coda60.json.
The CODA family shares one firmware image, so the app exposes WiFi, voice,
MoCA and router endpoints whether or not the SKU has the hardware. hitron coda60 resolves a profile first (explicit --model, then hw_model from the
root GET /deviceinfo, then Device.DeviceInfo.ModelName, then a
probe-refined generic profile) and only polls the endpoints that profile can
answer. A CODA60 — DOCSIS 4.0, one Ethernet port, no WiFi/voice/MoCA/USB — is
never asked for /WiFi/*, /MTA/*, /MoCA or the firewall.
specs/models.json is the catalog; src/hitron/adapters.py is the endpoint
registry that both the client and the verifier consume, and
specs/openapi-coda60.yaml is generated from it (python tools/gen_spec.py).
Two caveats that matter on real hardware: /WiFi/WPS and /MTA/StatusInfo
return 200 with empty hardware fields on a unit that has neither, so
detection keys on payload evidence rather than status codes; and an empty USB
list is an empty port, not an absent one.
Write/action — each is its own named subcommand (never a flag on the read
command), needs a login, and the destructive ones need --yes-really-do-this:
hitron coda60-reboot 192.168.100.1 --username admin --password admin --yes-really-do-this
hitron coda60-factory-reset 192.168.100.1 --username admin --password admin --yes-really-do-this
hitron coda60-hard-reset 192.168.100.1 --username admin --password admin --yes-really-do-this
hitron coda60-set-password 192.168.100.1 --username admin --password admin --old-password admin --new-password '...' --yes-really-do-this
hitron coda60-set-username 192.168.100.1 --username admin --password admin --new-username newadmin --yes-really-do-thisThese act on a real device the instant they run — see "Writes" below.
cli/ is a standalone hitron-cli for the same three families: a single
static binary, standard library only, no Python, no config file. Releases are
built for Linux, macOS, and Windows on amd64 and arm64.
cd cli && go build -o hitron-cli ./cmd/hitron-cli
./hitron-cli 192.168.100.1 # live view in a terminal
./hitron-cli stats --once # one report and exit
./hitron-cli detect 192.168.100.1
./hitron-cli channels --json
./hitron-cli monitor --interval 3s
./hitron-cli fec-reset --json # clear 3.0 + OFDM FEC counters, no login
./hitron-cli pwod --seed 12345678 # password of the day, computed offlineIt detects CODA6X, the experimental CODA 4x8x, CODA-57, and HT-EM5 itself, reads CODA6X and CODA-57
anonymously (prompting once if a device gates the read), uses HTTP Basic for
the HT-EM5, and checks every RF reading against the Midco envelope. In the live
view, 1 is the summary, 2 a live 6 MHz spectrum trace, and 3 the I/Q
constellation for one downstream port; the last two exist only on the CODA6X.
z resets the DOCSIS 3.0 and OFDM downstream FEC counters together on the
CODA6X, and x opens the guarded reboot dialog; those are the live view's only
writes. hitron-cli fec-reset does the counter clear headlessly, without
credentials, for scripts. hitron-cli pwod computes the CODA6X password of the
day offline, with no device contact. The destructive commands are separate
verbs with a y/N prompt that --confirm skips:
./hitron-cli reboot 192.168.100.1 -u admin -p admin
./hitron-cli factory-reset 192.168.100.1 -u admin -p admin --confirmFull command, flag, and auth reference: cli/README.md, or
hitron-cli help and hitron-cli help auth.
One process, one /metrics port, any combination of devices:
hitron-exporter --port 9877 \
--ht-em5 192.168.0.212 --ht-em5 192.168.0.241 --ht-em5 192.168.0.60 \
--coda60 192.168.100.1Or via environment variables (handy under systemd/Docker):
export HITRON_HT_EM5_HOSTS=192.168.0.212,192.168.0.241,192.168.0.60
export HITRON_CODA60_HOST=192.168.100.1
export HITRON_CODA60_MODEL=coda60 # optional: skip detection
export HITRON_EXPORTER_PORT=9877
hitron-exporterCODA6X/CODA-57 series use modem_* names matching the metric names an
earlier standalone exporter already used, so an existing Prometheus
scrape_config pointed at port 9877 needs no changes. New HT-EM5/MoCA series
use a hitron_ prefix.
The exporter detects each CODA6X model once per host (about ten GETs) and caches
it, so later scrapes only hit endpoints that SKU supports. Pass
--coda60-model / HITRON_CODA60_MODEL to skip detection.
hitron-exporter --coda60 192.168.100.1 # serve /metrics
hitron-exporter --coda60 192.168.100.1 --once --format telegraf # Influx line protocol
hitron-exporter --coda60 192.168.100.1 --once --format otlp # OTLP/HTTP JSON
hitron-exporter --coda60 192.168.100.1 --once --format json # debug snapshot
hitron-exporter --coda60 192.168.100.1 \
--otlp-endpoint http://collector:4318/v1/metrics \
--otlp-header "authorization=Bearer $TOKEN"The exporter normalizes every device into one set of Sample objects and then
encodes that set four ways, so a metric added once appears in Prometheus,
Telegraf, OpenTelemetry, and the JSON API together. Telegraf consumes the
line protocol through inputs.exec with data_format = "influx" — no plugin
to install.
Besides /metrics, the process serves /healthz (per-source up state and
errors), /api/v1/samples, and /api/v1/logs.
Label a target with name=host:
hitron-exporter --coda60 edge=192.168.100.1 --ht-em5 attic=192.168.0.212An experimental CODA 4x8x is polled read-only with --coda4x8x HOST (or
HITRON_CODA4X8X_HOSTS, comma-separated). Not verified on live hardware.
hitron grafana --dir deploy/grafana # regenerate dashboards + provisioning
cd deploy && cp .env.example .env && docker compose up -dGrafana lands on http://localhost:3000 with the Prometheus datasource and
both dashboards already provisioned: hitron-coda6x (RF, provisioning,
OFDM/OFDMA, Wi-Fi, hosts, MoCA, exporter health) and hitron-ht-em5 (MoCA
nodes, PHY rates, Ethernet counters). Eight Prometheus alert rules ship in
deploy/grafana/prometheus/rules/hitron.rules.yml. Importable copies are in
dashboards/; the tour is in docs/GRAFANA.md.
curl -fsSL https://hitron.netquor.dev/install.sh | bash -s -- --run --device 192.168.100.1
# or, from a checkout:
hitron site --device 192.168.100.1 --port 8000Serves site/ and proxies /proxy/... to the gateway, which is what makes the
in-page API console work despite mixed-content and CORS. Add --read-only to
answer GET/HEAD only and return 403 for reboots and other writes.
The site includes the full API browser generated from site/openapi.json, live
RF charts, the DOCSIS event log, a downloadable request log, and the dashboard
downloads. It is plain HTML/CSS/JS, so GitHub Pages can host it directly. Pages
cannot proxy, so the published console explains how to start the local one
instead of failing with a bare "fetch failed".
import asyncio
from hitron import HitronMocaClient, Coda60Client, Coda57Client
async def main():
async with HitronMocaClient("192.168.0.212") as bridge:
print(await bridge.get_all())
client = Coda60Client("192.168.100.1")
match = await client.detect_profile() # -> hw_model CODA60, capability-gated
print(await client.get_all(profile=match.profile))
print(await Coda57Client("192.168.100.1").get_all())
asyncio.run(main())specs/openapi-ht-em5.yaml, specs/openapi-coda60.yaml,
specs/openapi-coda57-legacy.yaml — OpenAPI 3.0, reverse engineered from live
devices and (for CODA6X) a static read of a real signed firmware image.
Not official Hitron documentation.
openapi-coda60.yaml is generated: paths, methods, capability tags and
per-firmware state come from src/hitron/adapters.py via tools/gen_spec.py.
openapi-coda4x8x.yaml is generated by the same script from the same registry
(read routes only, /1/Device prefix stripped) and is experimental: not verified
on live hardware. Only 24 of its 31 routes have a registry entry; the rest carry a
summary only (see docs/KB.md section 4).
specs/models.json is the model/capability catalog. Edit those, not the YAML.
pytestThe suite is offline and needs no device:
test_metrics.pynormalizes a real captured CODA-60 snapshot (intests/fixtures/) and checks channel power/SNR, counter parsing, OFDM locks, the disabled-OFDMA sentinel handling, uptime, provisioning, and the CODA-57 and HT-EM5 paths.test_formats.pypins the Prometheus exposition, Influx line protocol, OTLP/HTTP JSON, and JSON encoders.test_spec_site.pyvalidates the OpenAPI document (requiresopenapi-spec-validator), resolves every$ref, checks path parameters and unique operation IDs, and verifies the site spec, dashboards, deploy bundle, andllms.txtare consistent.test_coda60_write_payloads.py,test_coda57_spec_check.py, andtest_ht_em5_decode.pycover the original clients.
The Go client has its own offline suite:
cd cli && go vet ./... && go test ./...It uses httptest fixtures shaped like the captured responses, including the
null OFDM slots, -inf power sentinels, mixed IPv6/IPv4 WAN field, and
newest-first logs.
There is still no integration-test suite against real hardware — see
docs/KB.md §5.
Coda60Client has confirmed (not guessed) write/action methods, pulled
directly from the CODA6X firmware's own PHP source — not reverse engineered
from guesswork, and verified against ModelInfo.php/AdminPassword.php:
| Method | Device endpoint | What it does |
|---|---|---|
login(user, password) |
POST /1/Device/Users/Login |
Required before the other writes; keeps the session cookie for the rest of this client's life. reset_fec() does not need it. |
reboot() |
POST /1/Device/CM/Reboot, {"reboot":1,"factoryReset":0,"restoreReset":0} |
Sets a TR-181 reboot flag for a backend process to act on. Measured inert on 8.7.1.0.1b4: errCode 000, no reboot. |
factory_reset() |
same endpoint, {"reboot":0,"factoryReset":1,"restoreReset":0} |
Sets the factory-reset flag the same way. Destroys all configuration. Not measured. |
hard_reset_and_reboot() |
same endpoint, {"reboot":0,"factoryReset":0,"restoreReset":1} |
The PHP handler exec()s reboot directly — immediate, no flag indirection. Measured working: the socket closes with no reply, the unit is back about two minutes later. The point of no return. |
reset_fec() |
PUT /1/Device/CM/DsInfo, PUT /1/Device/CM/DsOfdm |
Clears the DOCSIS 3.0 and OFDM downstream FEC counters. Bare PUTs, no body, no login. The 3.0 stop is complete; the OFDM stop clears some channels per call and is retried. |
set_admin_password(...) |
POST /1/Device/Manage/Password |
Changes the admin password. |
set_admin_username(...) |
POST /1/Device/Manage/Username |
Changes the admin username. |
set_wifi_radio(index, settings) |
PUT /1/Device/WiFi/Radios/{index} |
Server-validated radio config write. |
The reboot body always carries all three flags: ModelInfo::doRebootAction()
reads every flag before it picks a branch, so a partial body is a PHP 8 fatal
(HTTP 500), not errCode 001.
Coda57Client has no write methods — the one script this project was
built from (hitron-client/main.py) never implemented one, and no write
endpoint for the legacy .asp API has ever been observed. Use
Coda60Client for any action; both are believed to be the same underlying
hardware/software generation (see docs/KB.md §3).
None of these are gated by a config flag or an environment variable — the
library does exactly what you call. That's deliberate: a write against a
real, in-service modem should be a traceable act with your name on it, not
something that happens because a flag was left on. The CLI adds its own
layer on top (separate subcommands, --yes-really-do-this for the
destructive ones) so a write is never one typo away from a read — but the
library itself trusts the caller. The metrics exporter never calls any of
these.
The experimental CODA 4x8x client has no write or action methods at all, by policy, and the exporter reaches it read-only.
The HT-EM5 units used to write this were lab/test bridges with default credentials, not production equipment. The CODA6X/CODA-57 covered here is a real, in-service cable modem on a real ISP account. Every write/action method above was added, confirmed, and committed without ever being run against that live device in this session — treat running one for the first time as its own deliberate decision, the same way you'd treat it if you were clicking the button on the device's own web UI.