Skip to content

About

Zephyr®-based Bluetooth® LE application for wireless stepper motor speed, direction, and start/stop control on Microchip PIC32-BZ6 boards using the Microchip Transparent UART Profile and MPPB.

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Latest commit

 

History

4 Commits

Folders and files

Repository files navigation

Bluetooth® LE Stepper Motor Control

Wireless step and direction control. Powered by Zephyr®.

Wireless MCU   |   Bluetooth LE   |   Full / half stepping

Set up Zephyr · Import · Build · Flash · Run with MBD

Contents

  1. Introduction
  2. Hardware Setup
  3. Zephyr Software Setup
  4. Application Architecture and Control Principles
  5. Demo Setup and Operation
  6. Validation and Troubleshooting

1. Introduction

Command step count, direction, step interval and start/stop wirelessly from the Microchip Bluetooth Data (MBD) app. The PIC32-BZ6 Curiosity board uses the Microchip Transparent UART Profile over Bluetooth® LE and sequences eight GPIO controls on the Microchip Multi-Phase Power Board (MPPB).

The example uses a Leadshine 42HS03 eight-lead, two-phase stepper. Full-step (FS) mode provides 200 commanded steps/revolution, and half-step (HS) mode provides 400. Press Curiosity User Button 2 (SW800) to switch modes.

Supported board: PIC32-BZ6 Curiosity only, pic32wm_bz6204_curiosity/pic32cx2051bz62132.

Disclaimer

This example is provided “AS IS” as a starting point for development and self-support. Motion is open-loop: commanded steps are not measured shaft position or speed. There is no encoder, homing, stall detection, acceleration ramp, current-feedback regulator or holding torque at STOP.

Check the electrical ratings, winding connections and actual current before running the motor. The application uses GPIO sequencing, not PWM current regulation. Do not copy the brushed-DC example's 24 V supply setup.

2. Hardware Setup

Bill of materials

Item Quantity Notes
PIC32-BZ6 Curiosity board 1 Only supported board: pic32wm_bz6204_curiosity
Microchip MPPB (EV35Z86A) 1 Four half-bridges; A/B drive winding 1, C/D drive winding 2
Leadshine 42HS03 eight-lead stepper (AC300024) 1 Identify and connect the half-coils in bipolar series
External 5 V / 3 A power supply 1 Used in the author's setup; see the supply-rating note below
Series resistors, at least 1 ohm / 2 W each 2 Passive winding-current limiting for the recommended 6 V setup; one per complete winding

Supply-rating note: The author uses a 5 V / 3 A supply. However, the MPPB's specified input range is 6–50 V; 5 V is below its specified minimum and is not a guaranteed operating configuration. For the recommended series-wound, low-speed bench setup, use a regulated 6 V external supply with an adjustable current limit set to approximately 1.5 A, together with the per-winding resistors described below. A 3 A supply rating is its available output capacity, not a motor-winding current limit.

Motor and supply ratings

The 42HS03 datasheet specifies approximately 4.6 ohms and 1.0 A per half-coil, 0.7 A RMS in bipolar series, and 1.4 A RMS in bipolar parallel. These are winding current ratings, not permission to apply 24 V directly to a winding.

For the documented series-wound, low-speed bench setup, use 6 V and at least 1 ohm / 2 W in series with each complete winding. At 10% below the nominal half-coil resistance:

Winding current <= 6 V / (2 × 4.6 ohms × 0.9 + 1 ohm) = 0.647 A

Verify the actual winding resistance and current. Set the supply current limit to approximately 1.5 A and check for heating before sustained operation. The resistors limit current passively; the firmware does not regulate it. They also reduce winding heating by reducing current, but should not be treated as an optional fix only after the motor becomes hot. Select current limiting before operation based on the actual supply voltage, winding resistance and motor current rating. If the motor heats excessively, stop and check winding current and wiring before continuing; increasing resistance reduces current and torque, and requires checking the resistor power rating.

⚠️ Power and wiring safety

Do not use the brushed-DC application's 24 V supply with this GPIO-only stepper setup. Although the MPPB supports 6–50 V input, the motor windings still require current limiting. Higher voltage/speed operation requires a verified per-winding chopper regulator or a dedicated current-limited driver. Keep supply voltage off MCU signal pins. STOP releases the windings: secure mechanisms that could move when holding torque disappears.

Wiring

Connect and inspect all wiring with power removed. The following table applies only to Curiosity; these are GPIO outputs, including pins that have alternate timer/PWM functions.

PIC32-BZ6 Curiosity board connected to the Multi-Phase Power Board and stepper motor

Function PIC32-BZ6 Curiosity pin MPPB control-header pin Purpose
Drive A High PA7 / mikroBUS 1 SDA (J903 pin 11) 26 Winding 1, A half-bridge high
Drive A Low PA3 / J701 pin 25 (GPIO header) 25 Winding 1, A half-bridge low
Drive B High PA1 / mikroBUS 2 RX (J905 pin 14) 24 Winding 1, B half-bridge high
Drive B Low PA0 / mikroBUS 2 TX (J905 pin 13) 23 Winding 1, B half-bridge low
Drive C High PB10 / J701 pin 2 22 Winding 2, C half-bridge high
Drive C Low PB12 / J701 pin 11 21 Winding 2, C half-bridge low
Drive D High PB11 / J701 pin 13 20 Winding 2, D half-bridge high
Drive D Low PB13 / J701 pin 15 19 Winding 2, D half-bridge low
Ground GND / J701 pin 3 Pin 40 (GND) Common control/power reference
Status LED PB7, active low Not connected to MPPB Advertising, connection and mode indication
Mode button User Button 2 / SW800 / PE3 (sw0 alias) Not connected to MPPB Toggle FS / HS

Use the Curiosity board guide and MPPB hardware guide to verify connector orientation and the hardware revision. J903 is mikroBUS socket 1; J905 is mikroBUS socket 2; J701 is GPIO header 1. The SDA, RX and TX pins listed above are used as GPIO outputs, not as I2C or UART signals. Leave QSPI, graphics and mikroBUS accessories using PB10/11/12/13 disconnected. The four C/D signals need extra jumper wires on the existing adapter harness.

Eight-lead motor connections

The documented setup uses the 42HS03 in bipolar-series winding configuration. See Figure 3(b), page 2 of the 42HS03 motor datasheet for the wiring image. For the lead colors shown in that diagram:

Motor winding Join and insulate Outer leads to MPPB outputs
1 (datasheet A+ / A−) Green + yellow Black to A; orange to B
2 (datasheet B+ / B−) Blue + white Red to C; brown to D

These are datasheet colors and an example output assignment; verify the lead diagram and coil pairs for the actual motor before wiring. Bipolar series describes the winding connections; the firmware separately supports full-step (FS) and half-step (HS) operation, selected with User Button 2 (SW800).

  1. Identify four independent half-coil pairs with a multimeter. Each half-coil is nominally 4.6 ohms; unrelated pairs should be open.
  2. Pair the correct two half-coils for each phase according to the motor's bipolar-series lead diagram. Match magnetic polarity. Each series winding should measure approximately 9.2 ohms before adding its resistor.
  3. Insulate each internal series junction; do not connect it to an MPPB output, ground or supply.
  4. Connect winding 1's outer leads to MPPB A/B, through its series resistor. Connect winding 2's outer leads to MPPB C/D, through its separate resistor.
  5. Connect regulated 6 V to the MPPB motor-power input and join the required control/power grounds. Never connect motor leads directly to the supply or MCU GPIO.

Wire colors and a motor serial number do not identify coil polarity. Use the lead diagram for the actual motor cable. The generic wiring diagram below shows topology only, not manufacturer lead colors.

flowchart LR
    MCU["Curiosity MCU<br/>Eight GPIO controls"] --> H["MPPB<br/>A/B and C/D bridges"]
    V["Regulated 6 V<br/>current-limited supply"] --> H
    subgraph W1["Winding 1 - bipolar series"]
        R1["Resistor >= 1 ohm / 2 W"] --- C11["Half-coil 1"]
        C11 --- J1["Insulated series junction"]
        J1 --- C12["Half-coil 2"]
    end
    subgraph W2["Winding 2 - bipolar series"]
        R2["Resistor >= 1 ohm / 2 W"] --- C21["Half-coil 1"]
        C21 --- J2["Insulated series junction"]
        J2 --- C22["Half-coil 2"]
    end
    H ---|"Output A"| R1
    H ---|"Output B"| C12
    H ---|"Output C"| R2
    H ---|"Output D"| C22
Loading

3. Zephyr Software Setup

3.1 Prerequisites

Complete the Zephyr Wireless environment setup using either supported workflow:

Use these guides for host tools, the Microchip Zephyr workspace/modules, SDK, OpenOCD and CMSIS-DAP programmer-mode setup. This application has been build-checked with the Microchip Zephyr 4.2.0 workspace and SDK 0.17.4. A generic upstream checkout alone does not supply all PIC32-BZ6 components. The Transparent UART implementation is included in this application's src directory.

Supported board: PIC32-BZ6 Curiosity only — pic32wm_bz6204_curiosity, SoC qualifier pic32cx2051bz62132.

Setup guide and supporting references

AN1307's dsPIC reference uses parallel windings, 24 V, ADC/PWM current regulation, acceleration and half/microstepping. Those capabilities are not implemented here; its supply settings must not be copied to this example.

3.2 Import the application

Clone into the workspace

For the Workbench workflow, clone from the workspace's applications directory:

git clone https://github.com/MicrochipTech/Bluetooth_LE_Stepper_Motor_Control.git

The repository contains application firmware, not Zephyr, its modules, the SDK or programmer tools.

Workbench

Follow Import existing application in Workbench. Select applications\Bluetooth_LE_Stepper_Motor_Control, choose pic32wm_bz6204_curiosity, qualifier pic32cx2051bz62132 if requested, and SDK 0.17.4.

CLI

As in the servo and DC guides, clone inside the Zephyr checkout's samples directory. The CLI commands assume the application is at ~/zephyrproject/zephyr/samples/Bluetooth_LE_Stepper_Motor_Control.

cd ~/zephyrproject/zephyr/samples
git clone https://github.com/MicrochipTech/Bluetooth_LE_Stepper_Motor_Control.git

See the Zephyr Wireless CLI workflow for environment and shell setup.

3.3 Application configuration

Layer Configuration / source Role
Bluetooth LE / Transparent UART prj.conf, Kconfig, trs.c, trs_server.c One BLE connection, CP commands, transparent data and flow control
GPIO pin mapping Curiosity overlay Eight stepper-* aliases, led3, and SERCOM5 disabled to free PA0/PA1
Motor parameters / command IDs app_stepper_motor.h 6 V UI metadata, 200/400 steps per revolution, default 5 ms interval
Bridge sequence / motion app_stepper_motor.c FS/HS states, dedicated workqueue, bounded/continuous motion and MTU-aware UI response
BLE / UART / button integration main.c Advertising, command dispatch, button mode change and LED indication
Build / sample metadata CMakeLists.txt, sample.yaml Explicit application sources and Curiosity-only build target

The firmware boots in FS mode. User Button 2 (SW800), mapped to the Zephyr sw0 alias, switches the runtime mode; there is no build-time FS/HS selection in this version. GPIO bridge outputs are configured inactive at startup.

Bluetooth LE requests ATT MTU 247; the peer negotiates the actual value. CONFIG_BT_GATT_CLIENT=y allows the application to request an MTU exchange for the stepper UI response.

3.4 Build the application

Workbench

Follow Build the application in Workbench. Use the selected Curiosity board and SDK. Use a pristine build when switching applications or reusing an old build directory.

CLI

Run from the Zephyr checkout directory using the application under samples:

cd ~/zephyrproject/zephyr
west build -p always -b pic32wm_bz6204_curiosity samples/Bluetooth_LE_Stepper_Motor_Control

Zephyr automatically applies the Curiosity overlay. Build output is generated under ~/zephyrproject/zephyr/build/. No precompiled image is required.

3.5 Program the board

Workbench

Follow Flash the application in Workbench. Select the OpenOCD runner and configure the supported debug probe as described in the setup guide.

CLI

Flash the build from the previous section:

cd ~/zephyrproject/zephyr
west flash

If OpenOCD reports unable to find a matching CMSIS-DAP device, check the USB cable, debug-probe mode/drivers and other software holding the probe. A successful build does not mean the new image has been programmed.

3.6 File structure

Bluetooth_LE_Stepper_Motor_Control/
|-- README.md
|-- .gitignore
|-- CMakeLists.txt
|-- Kconfig
|-- prj.conf
|-- sample.yaml
|-- boards/
|   `-- pic32wm_bz6204_curiosity.overlay
`-- src/
    |-- main.c
    |-- app_stepper_motor.c
    |-- app_stepper_motor.h
    |-- trs.c
    |-- trs.h
    |-- trs_server.c
    `-- trs_server.h

Build output and local VS Code settings are ignored, matching the servo repository.

4. Application Architecture and Control Principles

4.1 Control architecture

At a glance Application behavior
Advertising name Zephyr_Stepper_Motor
UI name Stepper Motor - FS or Stepper Motor - HS
Startup FS, 200 configured steps, 5 ms/step, CW, stopped
Resolution FS: 200 steps/revolution (1.8°); HS: 400 (0.9°)
Finite move Configured step count at the selected interval, then all bridges off
Continuous mode Delay 0; nominal 1 ms interval until STOP, step count ignored
Mode change User Button 2 (SW800) toggles FS/HS, resets configured steps to 200/400, stops an active move
Feedback Command state / completion notifications; no physical motion sensor
Power-stage control Eight GPIO outputs; no PWM current regulation

Diagrams use generic functional signals. The hardware table defines the actual Curiosity pin mapping.

flowchart LR
    M["MBD app<br/>Steps, interval,<br/>direction, start / stop"]
    subgraph MCU["Wireless MCU"]
        T["Transparent UART<br/>command validation"]
        S["FS / HS sequencer<br/>scheduled motor work"]
        G["Eight GPIO<br/>bridge controls"]
        B["User Button 2 (SW800)<br/>Mode button"]
        T <--> S
        B --> S
        S --> G
    end
    M <-->|"Bluetooth LE<br/>ACK, state, completion"| T
    G --> H["MPPB<br/>Two H-bridges"]
    H --> D["Two-phase<br/>stepper motor"]
Loading

4.2 Bluetooth LE data flow and commands

From a step request to motion

sequenceDiagram
    participant M as MBD app
    box Wireless MCU
        participant T as Transparent UART
        participant S as Stepper sequencer
        participant G as GPIO outputs
    end
    participant H as MPPB + motor
    Note over M,T: Connected, Control Point notifications enabled
    M->>T: Set steps, interval and direction
    T->>S: Validate and store next-move settings
    S-->>M: ACK, response and state notification via Transparent UART
    M->>T: START
    T->>S: Start configured move
    S-->>M: ACK and START state via Transparent UART
    loop Each scheduled step
        S->>G: Disable changing winding, wait 100 us, apply next state
        G->>H: Drive selected bridge controls
    end
    S->>G: All bridges off at finite-move completion
    S-->>M: STOP notification via Transparent UART
Loading

ACKs and completion report software execution, not confirmed shaft motion.

Transport and command frames

Motor commands belong on the Transparent UART Control Point (CP). Enable CP notifications before writing commands. RX data forwards transparent bytes to UART; it does not execute stepper commands. TX notifications carry UART-originated transparent data.

8E | LENGTH | COMMAND_ID | COMMAND_DATA

LENGTH counts the command ID and data bytes. Multi-byte step counts and intervals are unsigned 16-bit big-endian. Direction and start/stop are one-byte fields.

Request Raw example ACK Response / notification
Read UI/state 8E 01 A1 8E 01 D1 B1 UI update after sufficient MTU
Configure 200 steps 8E 03 A6 00 C8 8E 01 D6 8E 03 B6 00 C8, 8E 03 C6 00 C8
Configure 50 ms/step 8E 03 A7 00 32 8E 01 D7 8E 03 B7 00 32, 8E 03 C7 00 32
Configure CW 8E 02 A4 00 8E 01 D4 8E 02 B4 00, 8E 02 C4 00
Configure CCW 8E 02 A4 01 8E 01 D4 8E 02 B4 01, 8E 02 C4 01
START 8E 02 A5 01 8E 01 D5 8E 02 B5 01, 8E 02 C5 01
STOP 8E 02 A5 00 8E 01 D5 8E 02 B5 00, 8E 02 C5 00
Configure continuous mode 8E 03 A7 00 00 8E 01 D7 Delay 0 selects continuous mode on the next START

Step count is 1–65535. Nonzero delay is 1–65535 ms between steps, not total move duration. Step count and delay changes during a move apply to the next move. Changing direction during motion stops it; another START is required. Finite completion sends 8E 02 C5 00.

UI response layout

8E | LENGTH | B1 | NAME_LENGTH | NAME |
VOLTAGE_H L | STEPS_PER_REV_H L | STEP_COUNT_H L | DELAY_MS_H L | DIRECTION | START_STOP

Default FS response:

8E 1E B1 12 53 74 65 70 70 65 72 20 4D 6F 74 6F 72 20 2D 20 46 53 00 06 00 C8 00 C8 00 05 00 00

It reports Stepper Motor - FS, 6 V, 200 steps/revolution, 200 configured steps, 5 ms/step, CW and STOP. HS changes the name suffix to HS and reports 400 steps/revolution with 400 configured steps after a mode toggle. LENGTH is 0x1E (30); the full frame is 32 bytes. This needs an ATT MTU of at least 35 for a CP notification. After A1, the application requests MTU exchange if needed. If the peer refuses a sufficient MTU, B1 is not delivered; check the MTU error log.

4.3 GPIO sequencing and motor control

This application does not use a STEP/DIR driver or PWM speed/current control. The MCU directly selects the eight MPPB high/low controls.

FS state Winding 1 (A/B) Winding 2 (C/D)
0 A High + B Low (+) C High + D Low (+)
1 B High + A Low (-) C High + D Low (+)
2 B High + A Low (-) D High + C Low (-)
3 A High + B Low (+) D High + C Low (-)

CW traverses the states in forward order; CCW in reverse. HS inserts four one-winding states between the two-winding states. Each changing winding is disabled for 100 us before its new state is applied; unchanged windings stay energized.

Approximate commanded speed for a nonzero interval:

RPM = 60,000 / (steps_per_revolution × interval_ms)
Interval Nominal FS speed Nominal HS speed
50 ms 6 RPM 3 RPM
10 ms 30 RPM 15 RPM
5 ms (default) 60 RPM 30 RPM

These are commanded timing estimates, not measured speed. Scheduling and Bluetooth traffic may extend the move; missed steps may reduce actual travel. Finite steps use monotonic-clock deadlines with at least 1 ms between scheduled steps. Continuous mode uses nominal 1 ms intervals; it has no acceleration ramp and is not guaranteed to reach its theoretical speed.

At STOP, finite completion or a mode change during motion, all bridges turn off. There is no holding torque. HS torque varies between one- and two-winding states because no current regulation compensates the difference.

5. Demo Setup and Operation

The demo below shows the stepper motor controlled wirelessly using the MBD app.

IMG_2403.mov
Step Action Expected behavior
1 With power removed, verify coil pairs, series junctions, resistors and all eight control wires Two independent series windings and correct A/B/C/D connections
2 Program Curiosity and apply the verified bench supply FS mode, motor stopped, advertising as Zephyr_Stepper_Motor
3 Connect MBD and enable CP notifications Commands and state responses can reach the app
4 Request UI/state Stepper Motor - FS; MTU exchange if needed
5 Set 200 steps, CW and 50 ms/step, then START One nominal FS revolution, approximately 10 seconds, then coast
6 STOP, check winding current/temperature, then test CCW Opposite direction without excessive current or heating
7 Press User Button 2 (SW800) Double LED blink; HS mode, configured steps reset to 400; START required again
8 Request/check HS UI and run 400 steps at 50 ms/step One nominal HS revolution, approximately 20 seconds, then coast

Begin with a longer step interval, not continuous mode or the shortest delay. Increase speed only after checking winding current, supply limiting, heating, resonance and missed steps. There is no acceleration ramp.

For a manual BLE client, write the hexadecimal frames in the command table to CP. Do not send them as ASCII strings or through transparent RX.

⚠️ Disconnection is not STOP

Bluetooth LE disconnection detaches notifications but does not stop motion. A finite move continues to completion; continuous motion continues until stopped by a supported local action or reconnected STOP command. Send STOP before disconnecting. User Button 2 (SW800) stops an active move while changing mode.

6. Validation and Troubleshooting

The copied firmware preserves the existing application's behavior. A successful build checks compilation, not current limits, coil polarity, actual travel or safe mechanical operation. Validate those on the actual hardware.

Check Expected result
Startup FS, 200 steps configured, 5 ms interval, CW, stopped
FS/HS button Stops active motion, double blink, UI name and steps/revolution updated
GPIO routing All eight pins match the hardware table and overlay
Winding current Within the motor's series-winding rating under the documented supply arrangement
Bounded motion Configured number of state advances, then all outputs inactive
Direction Shaft direction agrees with CW/CCW after correct winding polarity
UI exchange B1 received with ATT MTU >= 35
Completion STOP notification; no winding hold after motion
Symptom Check
Vibrates without rotating Identify half-coil pairs, phase grouping/series polarity and A/B/C/D jumpers; stop before changing wiring
Supply limits current or motor heats Stop and check actual winding current, series resistors, resistance and 6 V supply; no active current regulation exists
Motion loses steps at short delays Lengthen interval, reduce load and check resonance; there is no acceleration ramp or stall feedback
Only one phase works Check the four extra C/D jumpers and disconnect conflicting accessories on PB10/11/12/13
Direction is reversed With power off, reverse the two outer leads of one complete winding and verify again
B1 UI response missing Enable CP notifications; peer must negotiate ATT MTU >= 35
Mode button has no effect Use User Button 2 (SW800); confirm the current image, sw0 mapping to PE3, button interrupt and mode logs
Changed count/delay does not affect running move Those settings apply to the next START
Motor continues after disconnect Expected open-loop behavior; disconnect is not a hardware stop
No holding torque after STOP Expected: all bridges off
OpenOCD cannot find CMSIS-DAP Check probe mode, USB, drivers and probe ownership; flashing did not complete