PclIO

PclIO is a .NET library and command line tool that reads point cloud files from several scanner and project formats and exports the points to LAS, XYZ, PTS and JSON, without the software that wrote the files.

What it does

  • Detects the format of a file or folder from its content, extension or layout (PclFile.DetectKind).
  • Opens a file as a PclDocument with its scans, bounds, transforms, metadata and warnings, and streams the points (ReadAllPoints, PclScan.ReadPoints) with a point limit, a subsampling step and an optional scan transform. Leica scans additionally read a block range with opt-in parallel decoding.
  • Exports to ASPRS LAS 1.2 (point format 2) and 1.4 (point formats 6 to 8), ASCII XYZ, ASCII PTS and JSON.
  • Ships the command line tool pclio with info, scans, points and export.

Install

PclIO is a preview (0.x). The packages are published on nuget.org, not on GitHub Packages, so the Packages box of this repository stays empty.

PclIO on NuGet PclIO.Cli on NuGet

Install the command line tool:

dotnet tool install --global PclIO.Cli

Add the library to a .NET project:

dotnet add package PclIO

The library targets .NET 8 and .NET 10. It is managed code with no dependencies on other packages (see third-party notices), has no native dependencies or Windows-only APIs, and is tested on Windows, Linux and macOS. It does not contact the network and writes nothing to the console.

Supported formats

Format Extensions Support level
ASTM E57 .e57 Points decoded for a defined subset: uncompressed bit-packed streams with single or double precision Cartesian coordinates or scaled-integer coordinates (raw value times scale plus offset), or spherical range, azimuth and elevation converted to Cartesian points, with 8-bit colour and 8-bit intensity, or colour with a wider Integer range from zero and intensity as a wider Integer, a Float or a scaled integer. Pose translation and rotation are applied. Only plain bit-packing is decoded: a scan whose codecs vector names another codec lists normally and fails when its points are read, and the message names it. Per-point validity flags skip invalid points and clear invalid channels when their streams hold one flag byte per record; other shapes are not interpreted. Images are not read, so a scan with them still lists and reads its points. Page checksums are verified.
ReCap scan .rcs Experimental. The header is read; point decoding covers the node layouts that are described in the code, which is the one of major version 3. A file of another version is listed with its header, but reading its points fails with a message that names the version. A further layout is described only when the files of that version may be used for the tests, so that its offsets can be verified. The channels of the points follow from the size of the payload of the nodes: colour and intensity when the records are long enough, and normals when the node holds the plane of them.
ReCap project .rcp Lists the scans of the project manifest and opens the .rcs files it finds next to the project. The transform of a scan node places the scan in the project and is applied to its points unless ApplyTransform is false; when the manifest states no transform, the transform of the scan file is used.
Leica scan container .lgsx, .lgs Experimental. Points are decoded from the compressed point blocks: position, and colour, intensity and normals when the block has them. When the container assigns its points to its setups, there is one scan per setup, named after the setup, with the pose and the bounds of the setup when its record holds them; the pose is applied unless ApplyTransform is false. When the container does not assign its points, all points of the container form one scan and a warning says so. The point count is taken from the container when it states one; otherwise it is found by decoding the data, which is slow on large files. PclReadOptions.Blocks reads only the blocks of the scan in that file-order range (per scan, so a setup scan ranges over its own blocks); PclReadOptions.MaxDegreeOfParallelism above 1 decodes those blocks in parallel and still yields the points in file order with consecutive Index values.
FARO scan .fls, or a FARO scan folder Experimental. The scan grid and angles are read from the stored parameters and points are projected from the range grid; a file without them fails to open. The point count is the number of valid returns, which is counted on the first access; FaroScan.GridSize is the size of the scan grid. For a scan folder the layout of the samples is derived from the size of the data stream and the size of the grid, and the scale of the intensity from the values that are stored; when the sizes do not fit, the layout is assumed and a warning says so.
PinPoint project .srf, .smf, or a folder with ScanProject.json or .smf/.srf files Experimental. The manifest (scan names, ids, poses, counts) is read. Points come from the referenced .bin files, in either of two layouts: a table of named channels, or numbered sections with a property table and Snappy-compressed channels, which PclIO decodes itself. Colour, intensity and normals are reported only when the file has that channel; in the second layout positions, colours, intensities, normals (Normals, three float32 components per point) and the per-point flags (FilterBits, one byte per point) are read, while the grid indices stored beside them are not interpreted, so by default every stored point that passes the plausibility rule below is returned. With PclReadOptions.ExcludeFilteredPoints the points with a non-zero flag are not returned. A manifest with a scan position list takes the point count from the manifest, else from the data file; a manifest with a data object list takes it from the data file the object refers to, and every location that shares one file reports its full count, because the shares are not recorded.
EdgeWise .c3db, .c3ptx Experimental. A .c3db point database lists the scan clusters and a .c3ptx is one cluster file; the cluster files give positions only, as three 16-bit offsets from the cluster centre per point. The scale of the offsets is not stored in the files, so the reader assumes 32768 units = 0.128 m unless the caller states it with PclReadOptions.EdgeWiseCoordinateScale.
LAS .las Points decoded from versions 1.0 to 1.4 with point formats 0 to 10: XYZ with scale and offset, intensity, classification and RGB for the colour formats (2, 3, 5, 7, 8, 10). GPS time, return numbers, scan angles, point source ids, near infrared and waveform packet descriptors are not interpreted; extra bytes past a format's base size are skipped. The extended point counts of 1.4 are used when stated. Coordinate system records name an EPSG: code from a GeoTIFF key directory when it holds one, else the OGC WKT when one is stored.
PCD .pcd Points decoded from the 0.7 header in ASCII, binary and binary compressed (LZF) form: XYZ from x, y and z, colour from packed rgb or rgba, intensity, and normals from normal_x, normal_y and normal_z. Points with non-finite coordinates are not returned. The viewpoint is kept as metadata and not applied.
PLY .ply Vertices decoded from ASCII and binary little and big endian files: XYZ from x, y and z, 8-bit colour from red, green and blue (with alpha when present), intensity, and normals from nx, ny and nz. Faces and other elements are ignored. Points with non-finite coordinates are not returned.
PTS .pts Leica Cyclone ASCII exchange point clouds: XYZ coordinates with or without point count header, intensity, 8-bit RGB colour, or unit normals across 3, 4, 6, 7, 8, 9 and 10 column layouts. Points with non-finite coordinates are not returned.
PTX .ptx Leica Cyclone gridded ASCII exchange point clouds: one or more gridded scans per file, each with a 10-line header defining grid dimensions (columns and rows), scanner position and axes, and a 4x4 transformation matrix. XYZ coordinates across 3, 4, 6 and 7 column layouts (with intensity and 8-bit RGB colour). Empty grid cells (coordinates 0, 0, 0) and non-finite coordinates are skipped. Transform matrices are applied to point positions unless ApplyTransform is false.
XYZ / text .xyz, .asc, .txt, .csv Delimited text point clouds: comma, semicolon, tab or whitespace delimiters; column layouts determined from a header line (e.g. x,y,z,nx,ny,nz), explicit PclReadOptions.TextColumns, or column count heuristics (3, 4, 6, 7, 8, 9, 10 columns for XYZ, intensity, 8-bit RGB colour or unit normals, and alpha). Comment lines (#, // or TextCommentPrefix) and points with non-finite coordinates are skipped. Coordinate scale applied via PclReadOptions.TextCoordinateScale.
SBF .sbf, .sbf.data Simple Binary Format point clouds: single-precision floating point XYZ coordinates and optional scalar fields (intensity, 8-bit RGB colour, unit normals) with an INI-style companion .sbf header file declaring point count, global shift and scale, and scalar field names. Big-endian and little-endian byte orders supported. Points with non-finite coordinates are not returned. Global shift and scale are applied via ApplyTransform.
3D Tiles .pnts, .glb, tileset.json OGC 3D Tiles point cloud tiles (.pnts, version 1) with float32 or quantised 16-bit positions (POSITION_QUANTIZED), RGB, RGBA, RGB565, or constant RGBA colour, float32 or octahedral oct16p normals (NORMAL_OCT16P), relative-to-center offsets (RTC_CENTER), and batch table scalar properties (Intensity, Classification). glTF 2.0 binary point clouds (.glb) with mesh primitive mode 0 (POINTS), reading POSITION, COLOR_0, NORMAL, and INTENSITY accessors and node transforms. Hierarchical 3D Tiles tilesets (tileset.json) or folders containing them, accumulating 4x4 transform matrices for referenced point tiles.
Potree cloud.js, metadata.json, .hrc, .bin Potree octree point cloud datasets: Potree 1.x (cloud.js manifest) with Cartesian scaled integer or float coordinates, 8-bit or 16-bit RGB/RGBA colours, float32, spheremapped or oct16p normals, intensities and classifications across node files (.bin) and hierarchy (.hrc). Potree 2.x (metadata.json manifest and octree.bin stream) with custom attribute schema layouts. Opening supported from manifest, hierarchy, individual node files, or dataset folders.
LAZ .laz LASzip compressed ASPRS LAS (versions 1.0 to 1.4, point formats 0 to 3): XYZ with scale and offset, intensity, classification and 8-bit RGB colour. Decoded via clean-room arithmetic decoder and integer decompressor with pointwise chunked compression (compressor 2) and pointwise uncompressed records (compressor 1). CRS is read from GeoTIFF or WKT VLRs. Point formats 6 to 10 with layered chunked compressor (compressor 3), waveform packets and EVLRs are not currently read.
COPC .copc.laz, .laz Cloud Optimized Point Cloud (COPC octree in LAS 1.4 / LAZ): reads the octree hierarchy (root and sub-hierarchy pages) and voxel bounding boxes, center, halfsize and spacing metadata, streaming points by octree node, bounding box or across the whole dataset. LAS formats 0 to 3 are fully decompressed via LASzip arithmetic decoding; LAS 1.4 formats 6 to 8 decode uncompressed anchor points with exact positions, intensity, classification and RGB colour per octree node.
EPT ept.json, .laz, .bin, .zst Entwine Point Tile (EPT octree datasets): reads dataset manifest (ept.json), octree hierarchy (ept-hierarchy/), and point data tiles (ept-data/) across "laszip", "binary", and "zstandard" storage types. Supports schema dimension extraction (XYZ, intensity, classification, RGB colour, normals), spatial querying by bounding box (FindNodes, ReadPoints), depth filtering, and single-node streaming.
Leica PTG .ptg Leica Cyclone gridded binary exchange point clouds: binary scan files (.ptg) with 8-byte signature and magic (0x928FA3C7), ASCII metadata header (NumRows, NumCols, %%properties, %%transform), column offset array, and column validity bitmasks with single or double precision Cartesian XYZ coordinates, intensity [0..1] and 8-bit RGB colour. Top-level ASCII index files (.ptg) referencing binary scan files are aggregated into multi-scan documents. Coordinate transforms applied unless ApplyTransform is false.
CC BIN .bin CC BIN binary entity files (*.bin, signature CCB2): single or multi-cloud datasets with 32-bit floating point Cartesian XYZ coordinates, global shift and scale vectors, 8-bit RGB colour arrays, 4x4 coordinate transform matrices, and scalar fields (including intensity). The reader applies the stored matrix, divides by the global scale and subtracts the global shift unless ApplyTransform is false. Points with non-finite coordinates are skipped. Scalar values beyond the declared field length are absent. Packed normals are supported in file versions 41, 42 and 50.

Format detection

PclFile.DetectKind finds the kind from the content of the file, its extension or the layout of a folder, and returns PclFileKind.Unknown for anything else; PclFile.Open then throws NotSupportedException. Extensions are compared without regard to case.

  • E57, ReCap scan and Leica files are recognised by their content and accepted with any extension; for Leica, .lgs selects the older container and any other extension .lgsx. EdgeWise files are also recognised by content when the extension is none of its own. A LAS file is recognised by the LASF signature with any extension except .laz and .copc.laz. A LAZ file is recognised by the LASF signature, a valid LASzip VLR and the .laz extension. A COPC file is recognised by the LAS 1.4 header and the copc info variable length record with .copc.laz or any extension. A PCD file is recognised by its header structure with any extension. A PLY file is recognised by its magic word and header structure with any extension. A PTS file is recognised by an integer point count header line followed by coordinate lines with any extension, or coordinate lines with the .pts extension. A PTX file is recognised by its 10-line header structure (grid dimensions, scanner pose, 4x4 matrix) with any extension. An XYZ / delimited text file is recognised by an explicit column header containing X, Y, Z in any extension, or by numeric coordinate lines with a recognised extension (.xyz, .asc, .txt, .csv). An SBF file is recognised by its companion [SBF] header structure with any extension, or by the binary signature 0x2A, 0x2A (**) and record size formula (.sbf, .sbf.data, .data). A 3D Tiles .pnts tile is recognised by the pnts signature, version 1, and matching byte lengths. A glTF .glb point cloud is recognised by the glTF signature, version 2, and mesh primitive mode 0 (POINTS). A 3D Tiles tileset is recognised by JSON containing asset and root objects (tileset.json). A Potree dataset is recognised by cloud.js (with octreeDir and attribute descriptors) or metadata.json (version 2.x and point attributes) in .js or .json, by .hrc hierarchy files with 5-byte node records, or by ancestor cloud.js/metadata.json next to a .bin file. An EPT dataset is recognised by ept.json manifest structure (bounds, dataType, schema) or by companion ept.json next to octree tiles. A Leica PTG binary scan file is recognised by the PTG\0 tag and magic number 0x928FA3C7 with any extension; a top-level ASCII index file is recognised by the PTG index header and the .ptg extension. A CC BIN file is recognised by the CCB2 signature and entity header structure with any extension; a recognised Potree manifest in an ancestor directory takes precedence for .bin files.
  • A FARO file must be an OLE2 compound file with the extension .fls. A ReCap project must be a ZIP archive with the extension .rcp. A PinPoint file must be a JSON text file with the extension .smf or .srf.
  • The extensions .c3db and .c3ptx select EdgeWise without a content check. A .c3ptx file is read as one cluster file and any other EdgeWise file as a point database.
  • A folder is a FARO scan folder, a PinPoint project folder (it holds ScanProject.json, or a .smf or .srf file), a 3D Tiles dataset (it holds tileset.json), a Potree dataset (it holds cloud.js or metadata.json), or an EPT dataset (it holds ept.json) by its layout.

So a wrong or damaged file with a recognised extension is reported as unknown, except .c3db and .c3ptx: those are reported as EdgeWise and fail with InvalidDataException when they are opened. A path that is neither a file nor a folder throws FileNotFoundException. The exact rules and their order are covered by the tests.

Referenced files and path containment

Reading never executes code from a file. File names stored inside project files (ReCap, PinPoint, EdgeWise) are joined to a base folder and rejected when they are empty, rooted, contain invalid characters, or resolve outside that folder. This check is lexical: the path is normalised and compared with the base folder, and symbolic links and junctions are not resolved, so a link inside the project folder counts as part of it. A rejected name is reported as InvalidDataException, or as a warning where the reader can carry on without the file. The FARO folder reader searches the folder it was given and does not use names from the data.

Where the readers look for the files a project refers to:

  • ReCap project: for each scan node, the stored path relative to the project's folder, then the project's support folder, then the project's folder, and last a file named after the scan in the support folder. A scan whose file is not found stays listed, yields no points and adds a warning.
  • PinPoint: the data folder that belongs to the project file, then the folder of the opened project file or folder. Where several data files match a scan, the first one in ordinal path order is used.
  • EdgeWise database: each cluster file is named relative to the database's folder; a missing one is skipped with a warning.
  • SBF: when opening a .sbf header file, the reader looks for a companion .sbf.data or .data binary file in the same directory. When opening a .sbf.data or .data file, it looks for a companion .sbf header file.
  • 3D Tiles tileset: referenced tile contents (.pnts, .glb, or external .json tilesets) are resolved relative to the directory of tileset.json; missing content files are reported with a warning.
  • Leica PTG index: relative scan paths referenced by an index file are resolved inside the index file's directory; path traversal outside the directory is rejected.

Data filters

These readers drop data without an error or a warning, so a scan can yield fewer points than PointCount.

  • Every exporter, and the points command with --format xyz or pts, skips a point with a NaN or infinite coordinate; the count is reported (see Exporters).
  • FARO: a grid cell without a valid return, or with a distance outside 0.1 m to 350 m, is not read. The point count of the scan is the number of the cells that are read, so it matches what a full read returns. A scan folder whose data stream does not hold a whole number of samples for the grid is read with the assumed layout of eight bytes per sample, and a warning says so.
  • PinPoint: a point with a NaN or infinite coordinate is never returned, and neither is a point with a coordinate whose magnitude exceeds PclReadOptions.MaxCoordinateMagnitude in the file's own unit (5000 by default, null for no limit). This is a plausibility rule of the reader, so coordinates in a projected system with large offsets are dropped by default. A full read reports how many points it dropped in the warnings of the document, and fails instead with PclReadOptions.Strict. A data file in neither layout, or in the sectioned layout with an element type or header value the reader does not support, cannot be read: the project lists it with a warning and reading its points throws NotSupportedException. A compressed stream whose copies reach back more than 8 MiB is not decoded: reading its points throws NotSupportedException, without an earlier warning.
  • Leica: padding entries and points that coincide with a block's origin are dropped, a compressed stream above its size limit is skipped, and a block that is not recognised ends the scan. The reader counts what it dropped or skipped and reports it in the warnings of the document, so that an incomplete result is visible. With PclReadOptions.Strict the read fails instead.
  • EdgeWise: a database node whose point count is 0 is skipped.
  • PCD: a point with a NaN or infinite coordinate is not returned; a colour, intensity or normal field whose shape the reader does not convert stays unread, so the points come without that channel.
  • PLY: a vertex with a NaN or infinite coordinate is not returned; colour that is not stored as 8-bit integers is left unread, with a warning.
  • PTS: a point with a NaN or infinite coordinate is not returned.
  • PTX: empty grid cells (0, 0, 0) and points with a NaN or infinite coordinate are not returned.
  • Leica PTG: invalid grid cells (flagged 0 in the column bitmask) and points with a NaN or infinite coordinate are not returned.
  • XYZ / text: a point with a NaN or infinite coordinate is not returned; comment lines are skipped.

Limits

A file that exceeds one of these limits, or whose declared sizes and counts do not fit the file, is rejected with InvalidDataException, with the exceptions below. A FARO scan grid above its limit gives NotSupportedException when the file is opened. An E57 point prototype with more than 65535 fields gives NotSupportedException when the points are read; the scan still lists. A scan whose codecs vector names another codec than plain bit-packing is rejected the same way, and the message names it. A compressed Leica stream above its size limit is not rejected: its data is skipped and the skip is reported in the warnings of the document, which is one of the Leica data filters above. An unsupported PinPoint feature (see the data filters) gives NotSupportedException when the points are read. Point data is streamed and there is no limit on the file size, except for FARO container files: each compressed data stream is read into memory as a whole, so its size must fit a .NET array (about 2 GB), otherwise reading fails with NotSupportedException. The XML of E57 and ReCap project files is read with DTDs prohibited, so no entity is expanded and nothing outside the file is fetched.

Format Limits
E57 XML section 32 MiB, nesting depth 64, 1,000,000 elements; declared record counts up to 2^40; at most 65535 fields in a point prototype; at most 4096 consecutive packets without points.
ReCap project Manifest 64 MiB (declared and real size), nesting depth 64, 1,000,000 elements, 65,536 scan nodes.
ReCap scan 500,000 nodes in the node table, which must fit in the file together with the node payloads.
Leica 10,000 container entries; per point block at most 64 compressed streams, 10,000,000 compressed bytes per stream, 16 MiB per decompressed stream (checked before allocation) and 128 MiB decompressed in all; over all blocks of one read 1 GiB plus 64 times the file size decompressed.
FARO Parameters 1 MiB; scan grid of at most 2^27 cells (134,217,728); a distance stream too small for the declared grid is refused; each compressed data stream is held in memory (see above) and is inflated in chunks, and must not inflate beyond its grid size plus 64 KiB. Compound file: 65,536 directory entries, depth 16.
PinPoint Manifest 64 MiB and the default nesting depth of System.Text.Json (64); 100,000 scans. The parsed manifest needs memory of about 15 times its size, so a manifest at the limit needs about 1 GB. Sectioned data file: at most 16 sections, a property table of at most 1 MiB nested at most 8 levels, copies in a compressed stream at most 8 MiB back with a decoder window of at most 8 MiB per stream; the sections must be contiguous and fill the file, and the Points, RGB8, Intensities8, Normals and FilterBits streams must decode to exactly 12, 3, 1, 12 and 1 bytes per stored point.
EdgeWise 1,048,576 characters per database line; 1,000,000 nodes. Patterns that parse a line have a time limit.
LAS Header of at least 227 bytes (375 for 1.4); at most 4096 variable length records of at most 1 MiB each; point records at most 1 MiB.
PCD 4096 header lines of at most 1 MiB each; at most 1024 fields with an element count of at most 65536; decompressed binary data at most 1 GiB.
PLY 4096 header lines of at most 1 MiB each; at most 1024 elements with at most 1024 properties each; vertex records at most 1 MiB.
PTS Lines of at most 1 MiB each; declared point count cannot exceed the physical capacity of the file.
PTX Lines of at most 1 MiB each; declared grid counts cannot exceed the physical capacity of the file.
Leica PTG Metadata header up to 1 MiB; dimensions up to 100,000 rows and columns; grid cells up to 1,000,000,000; column offset table within file bounds; bitmask and point record byte counts checked against file size.
XYZ / text Lines of at most 1 MiB each; point count cannot exceed the physical capacity of the file.
3D Tiles Binary chunk length and feature/batch table lengths checked against file size; glTF accessor bounds and byte strides checked against buffer view sizes.
Potree Manifest 16 MiB; point record size up to 1 MiB; node binary file length must be an exact multiple of record size.
LAZ Chunk count and chunk byte sizes checked against file size; chunk size up to 100,000,000 points.

Exporters

Output Class Notes
LAS 1.2, point format 2
LAS 1.4, point formats 6 to 8
PclLasExporter (PclLasOptions selects version, format, scale, offset and coordinate system record) Position, intensity, classification, RGB (formats 2 and 7/8; format 8 adds a zero near infrared). 1 mm scale and offset from the data by default. A projected EPSG:NNNN coordinate system of the source is written as a GeoTIFF record for LAS 1.2 only when asked; LAS 1.4 requires WKT, which the exporter does not produce, so a 1.4 file carries no coordinate system record.
XYZ PclXyzExporter X Y Z R G B when the point has a colour, else X Y Z I when it has an intensity, else X Y Z.
PTS PclPtsExporter A line with the point count, then X Y Z Intensity R G B per point.
JSON PclJsonExporter Metadata and scans; sample points only when a point limit above zero is given.

XYZ and PTS output is culture independent (. decimal separator) and ends lines with \n. JSON output is culture independent; its line ends are those of the platform. Points with a NaN or infinite coordinate are skipped; the overloads with out long skippedPoints report how many, and the command line prints warning: skipped N points with a NaN or infinite coordinate on standard error when N is not zero. The exception is pclio points --format json, which skips nothing and writes such a coordinate as the string "NaN", "Infinity" or "-Infinity". Files written by export are UTF-8 without a BOM; info, scans and points write to the console with the platform's own line ends and encoding, and control characters in names and messages are printed as \uXXXX.

Command line

pclio info <file> [--json]
pclio scans <file> [--json]
pclio points <file> [--scan <id>] [--limit <n>] [--step <s>] [--format <xyz|pts|json>] [--no-transform]
pclio export <input> <output> [--format <las|xyz|pts|json>] [--limit <n>] [--step <s>] [--no-transform] [--force]
pclio <input> [--json]               same as 'info'
pclio <input> <output> [options]     same as 'export'
  • info prints the format, file size, scans, point count, bounds, coordinate system, metadata and warnings.
  • scans lists the scans with their point counts, channels, bounds and translation.
  • points prints points to standard output, at most 1000 unless --limit is given. --scan selects one scan by 0-based index, id or name. --format xyz and --format pts print the same lines as the exporters (PTS starts with its count line); --format json prints one JSON object per line.
  • export writes a file. The format comes from --format or from the output extension (.las, .xyz, .pts, .json); any other extension needs --format. The output is written to a temporary file next to the target and moved into place when complete. Export refuses to write to the input (compared after following links and junctions, and on Windows by file identity, so the verbatim and device prefixes and administrative shares are caught too; hard links are not detected elsewhere), to a path inside an input folder, to a missing folder or to a directory, and refuses to replace an existing file unless --force is given.
  • --limit and --step take integers of at least 1. --no-transform returns coordinates as stored. A JSON export rejects --step and --no-transform, and --limit for it is the number of sample points.
  • --help, -h and help, and --version, -v and version, print and exit with code 0.

Errors are one line on standard error, with no stack trace for any exit code.

Exit codes

Code Meaning
0 The command succeeded.
1 The command line is wrong: unknown option, missing or extra argument, invalid value, output refused.
2 The input cannot be read: it is missing, empty or unreadable. A failed write of the output also exits with 2, and the message names the file.
3 The input is corrupt, truncated or unsupported.
4 Unexpected internal failure.

Library

using System;
using System.IO;
using PclIO;
using PclIO.Export;

using PclDocument doc = PclFile.Open("scan.e57");
Console.WriteLine($"{doc.Kind}: {doc.Scans.Count} scans, {doc.TotalPointCount} points");

foreach (string warning in doc.Warnings)
{
    Console.Error.WriteLine(warning);
}

foreach (PclPoint point in doc.ReadAllPoints(new PclReadOptions { MaxPoints = 1000 }))
{
    Console.WriteLine($"{point.X} {point.Y} {point.Z}");
}

using FileStream output = File.Create("scan.las");
long written = PclLasExporter.Export(doc, output);

PclFile.Open throws FileNotFoundException for a missing path, DirectoryNotFoundException when a directory it needs disappears while reading, NotSupportedException for an unrecognised format or an unsupported feature, and InvalidDataException for a malformed or truncated file. The library is silent: problems that do not stop reading are collected in PclDocument.Warnings.

See the public API for the supported surface and dependencies for package details.

Documentation

Getting started, the public API, dependencies and private test fixtures are in docs/. The documentation site with the API reference is at https://ioextend.github.io/PclIO/, built from them with DocFX (docfx.json). Ask DeepWiki offers an automatically generated overview of the repository.

Limitations

  • Version 0.1.0 is a preview. The API can change before 1.0.
  • Only the subsets listed under Supported formats are read. Anything else fails with exit code 3 (InvalidDataException or NotSupportedException in the library) instead of being guessed, apart from the assumptions named under Supported formats (the FARO folder record layout and the EdgeWise position scale unless the caller states it with PclReadOptions.EdgeWiseCoordinateScale).
  • The decoders other than E57 cover only the file layouts they were written for. Files written by other software versions can be rejected.
  • Readers limit the sizes and counts that a file declares; the numbers are listed under Limits. A file that exceeds a limit is rejected, with the exceptions described there. Some readers drop points that fail a plausibility rule; see Data filters.
  • SubsampleStep is applied inside each format's internal blocks, so the spacing is approximate. MaxPoints limits one read call.
  • Blocks selects the blocks of a scan in file order and is honoured only by the Leica reader; other readers read the whole scan and ignore it. MaxDegreeOfParallelism above 1 decodes the selected Leica blocks in parallel and still yields the points in file order; other readers read sequentially and ignore it. Sequential Leica decoding holds one block at a time, while the parallel read holds the decoded points of the selected blocks. The default is 1: sequential streaming.
  • A scan transform is scale and translation, or a 4x4 matrix when the format gives one. Rotation values of a PclTransform are stored for information and are not applied by TransformPoint.
  • LAS and PTS export read the source twice (the header needs the count), so the source must be re-enumerable; memory does not depend on the number of points. A point without intensity is written with full intensity and a point without colour as white, because these formats have no "missing" value. LAS stores coordinates with the configured scale (1 mm by default), so the extent of each axis must fit 32-bit integers at that scale; the default offset is the minimum of the data.
  • Normals are read where a format has them, but no exporter writes them.
  • There is no support for writing or modifying scan files.

Build from source and tests

Use the .NET SDK selected by global.json, which specifies 10.0.100 with latestFeature roll-forward.

From the repository root:

dotnet build PclIO.slnx -c Release
dotnet test

Tests that need real scan files are skipped with a message unless PCLIO_TEST_FILES points to a folder with private fixtures (or an uncommitted test_files folder exists). The repository contains no scans. See private test fixtures.

Contributing

See CONTRIBUTING.md and the Code of Conduct. Release changes are recorded in CHANGELOG.md.

Security

Report vulnerabilities through GitHub private vulnerability reporting in the repository's Security tab. Do not open public issues for security vulnerabilities. See SECURITY.md.

License and trademarks

PclIO is licensed under the MIT License. Copyright holder: mahach666.

PclIO is not affiliated with, endorsed by or sponsored by Autodesk, Leica Geosystems, FARO, ClearEdge3D, PointCab or any other vendor named in this repository. Autodesk and ReCap are trademarks of Autodesk, Inc.; Leica and Leica Geosystems, FARO, EdgeWise, PointCab and PinPoint are trademarks of their respective holders. These names are used only to say which file formats PclIO reads. LAS is a format of the American Society for Photogrammetry and Remote Sensing (ASPRS), and E57 is an ASTM standard. No vendor code or binaries are included.

About

Reads point cloud files (.e57, Autodesk ReCap .rcp/.rcs, Leica .lgsx/.lgs, FARO .fls, PinPoint/PointCab .srf/.smf/.bin) without vendor software. Pure managed code, no dependencies.

Topics

Resources

Code of conduct

Contributing

Security policy

Stars

0 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages