  • Add an opt-in managed writer for the native 448 container, including its directory checksum, triangle buffers, materials, fragments, element tree, GUIDs, and display properties.
  • Keep the existing writer entry points and layout.

Verification

  • Full NwcIO solution tests and formatting passed locally on the current change.
  • RvtIO generated a cache for the public Autodesk rst_basic_sample_project.rvt on .NET 8 and .NET 10 in separate network-disabled Linux containers with no Autodesk software or files.
  • NwcIO reopened both outputs. The 484 mesh owners and names, 84,494 ordered triangles, and model GUIDs matched the source. Maximum world-space position error was 0.862 micrometres.
  • Navisworks Manage 2027 opened both outputs, with geometry under the expected 453 element GUIDs and all 455 element GUIDs present. It also saved the .NET 10 output as NWD.

The native writer supports triangle models with known units and baked rotation and scale. It needs only the managed .NET runtime.